![ABB ACSM1 Series Скачать руководство пользователя страница 229](http://html.mh-extra.com/html/abb/acsm1-series/acsm1-series_manual_2326229.webp)
Parameters and firmware blocks
229
(28)
ENC2 DI2=0 z
Encoder 2 position
First zero pulse when DI2 = 0
(29)
PROBE1 SW
Encoder 1 position
The trigger signal is selected by
parameter
(30)
PROBE2 SW
Encoder 1 position
The trigger signal is selected by
parameter
62.16
PROBE1 POS
(see above)
Defines the reference position for position probe 1.
The unit depends on parameter
selection.
-32768…32768
Reference position for position probe 1.
62.17
TRIG PROBE2
(see above)
Defines the position data source and triggering condition used for probe 2 latching. When the
triggering condition is fulfilled, the position received from the selected data source is set as probe 2
position.
In case the triggering condition is dependent on the zero pulse, the probe is latched upon the rising
edge of the zero pulse. The source of the zero pulse is defined by parameter
.
For selections, see parameter
.
62.18
PROBE2 POS
(see above)
Defines the reference position for position probe 2.
The unit depends on parameter
selection.
-32768…32768
Reference position for position probe 2.
62.19
MAX CORRECTION
(see above)
Defines the maximum absolute value for cyclic correction. Example: If maximum value is set to 50
revolutions and the requested cyclic correction is 60 revolution, no correction is made.
The unit depends on parameter
selection.
0…32768
Maximum absolute value for cyclic correction.
62.20
POS ACT OFFSET
(see above)
Offsets all the position values used by the position system, effectively correcting the position and
revolution count signal received from the encoder. For example, this parameter can be used if a non-
zero position signal received from the encoder needs to be defined as the zero position for the
application.
For example, if this parameter is set to a value of -100, the absolute position of 100 revolutions as
measured by the encoder is interpreted as the zero position.
Notes:
• The offset takes effect upon the next power-up or when an encoder reconfiguration command is
given using parameter
• The offset will not be visible through any actual signal or other parameter.
-32768…32768
Offset for actual position value.
Содержание ACSM1 Series
Страница 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Страница 4: ......
Страница 34: ...Drive programming using PC tools 34 ...
Страница 86: ...Drive control and features 86 ...
Страница 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Страница 302: ...Parameter data 302 ...
Страница 422: ...Application program template 422 ...
Страница 430: ...Appendix A Fieldbus control 430 ...
Страница 500: ...Appendix D Application examples 500 ...
Страница 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Страница 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...