8-18
–
+
ELEC
CHARGING SYSTEM
TROUBLESHOOTING
1. Connect:
• Pocket tester
(to the battery terminals)
2. Measure:
• Battery voltage
OK
BATTERY IS NOT CHARGED.
Battery voltage:
more than 12 V at 20 °C (68 °F)
OUT OF SPECIFICATION
• Check the battery.
• Replace and/or charge the battery.
Refer to “BATTERY INSPECTION” in CHAP-
TER 2.
3. Start the engine and accelerate to 5,000 r/min.
NOTE:
Place the machine onto a suitable stand to raise
the track off of the ground.
4. Measure:
• Charging voltage
CAUTION:
Never disconnect the battery cables while the
generator is operating; otherwise, the rectifier/
regulator will be damaged.
OK
Charging voltage:
14 V/5,000 r/min
OUT OF SPECIFICATION
• Check the main fuse.
Refer to “FUSE INSPECTION” in CHAPTER 2.
• Check the stator coil.
OK
FAULTY
Replace the main fuse and/or the sta-
tor coil assembly.
Replace the rectifier/regulator.
OK
Correct the connector.
Check the charging system’s wiring. Refer to
“CIRCUIT DIAGRAM”.
FAULTY
Properly connect or repair the charging system’s
wiring.
Summary of Contents for RS90K
Page 2: ......
Page 8: ......
Page 65: ...INSP ADJ ...
Page 158: ...2 57 INSP ADJ CARBURETOR TUNING Guide for carburetion ...
Page 195: ...INSP ADJ ...
Page 659: ... ELEC ...
Page 721: ... ELEC ...
Page 816: ...9 33 SPEC CABLE ROUTING 1 7 2 3 4 6 5 A A A A ...
Page 824: ...9 41 SPEC CABLE ROUTING 3 J K I H G F E D C B A 0 9 8 7 4 5 6 2 1 ...
Page 826: ...9 43 SPEC CABLE ROUTING 3 J K I H G F E D C B A 0 9 8 7 4 5 6 2 1 ...
Page 828: ...9 45 SPEC CABLE ROUTING A B B 1 2 3 4 5 6 7 8 9 0 A B 9 C 0 D E G F B B A ...
Page 830: ...9 47 SPEC CABLE ROUTING 1 5 2 3 4 A B 6 5 7 8 9 0 A C A A B B B A A B ...
Page 832: ...9 49 SPEC CABLE ROUTING A A 7 1 2 3 4 6 5 ...
Page 834: ...9 51 SPEC CABLE ROUTING 1 2 3 4 5 6 7 5 B B A A 8 9 4 4 A A B B ...
Page 836: ......
Page 839: ......