9-
44
T
roubleshooting
9
1. Error Messages
22.40 : PCMCIA interface overtime
Code
: &H1628
Meaning/Cause
: 1. Failed to acquire access privilege for PCMCIA interface.
Action
: 1. Replace the PCMCIA interface driver.
: 2. Replace the controller.
Dedicated output
: *1
22.41 : OPT.1 interface overtime
Code
: &H1629
Meaning/Cause
: 1. Failed to acquire access privilege for interface with option
board connected to option slot 1.
Action
: 1. Replace the option board connected to option slot 1.
: 2. Replace the controller.
Dedicated output
: *1
22.42 : OPT.2 interface overtime
Code
: &H162A
Meaning/Cause
: 1. Failed to acquire access privilege for interface with option
board connected to option slot 2.
Action
: 1. Replace the option board connected to option slot 2.
: 2. Replace the controller.
Dedicated output
: *1
22.43 : OPT.3 interface overtime
Code
: &H162B
Meaning/Cause
: 1. Failed to acquire access privilege for interface with option
board connected to option slot 3.
Action
: 1. Replace the option board connected to option slot 3.
: 2. Replace the controller.
Dedicated output
: *1
22.44 : OPT.4 interface overtime
Code
: &H162C
Meaning/Cause
: 1. Failed to acquire access privilege for interface with option
board connected to option slot 4.
Action
: 1. Replace the option board connected to option slot 4.
: 2. Replace the controller.
Dedicated output
: *1
22.45 : DRIVER interface overtime
Code
: &H162D
Meaning/Cause
: 1. Failed to acquire access privilege for interface with driver.
Action
: 1. Replace the driver.
2. Replace the controller.
Dedicated output
: *1
Summary of Contents for RCX40
Page 1: ...User s Manual ENGLISH E YAMAHA 4 AXIS ROBOT CONTROLLER E75 Ver 12 00 RCX40 ...
Page 2: ......
Page 16: ...viii MEMO ...
Page 18: ...MEMO ...
Page 24: ...1 6 MEMO ...
Page 26: ...MEMO ...
Page 34: ...MEMO ...
Page 284: ...MEMO ...
Page 308: ...5 24 MEMO ...
Page 310: ...MEMO ...
Page 318: ...6 8 MEMO ...
Page 320: ...MEMO ...
Page 328: ...7 8 MEMO ...
Page 330: ...MEMO ...
Page 336: ...MEMO ...