9-
31
9
T
roubleshooting
1. Error Messages
14.22 : No start code (@)
Code
: &H0E16
Meaning/Cause
: Starting code "@" was not added at beginning of single line in
an on-line command.
Action
: Add starting code "@" at the beginning of on-line command.
14.23 : Illegal command,Operating
Code
: &H0E17
Meaning/Cause
: During data editing, an on-line command was executed.
Action
: After completing data edit, execute an on-line command.
14.24 : Illegal command,Running
Code
: &H0E18
Meaning/Cause
: During program run, a non-executable on-line command was
attempted.
Action
: After stopping the program, execute the on-line system com-
mand which could not previously be executed.
14.25 : Illegal command in this mode
Code
: &H0E19
Meaning/Cause
: Cannot execute the specified online command in the current
mode.
Action
: 1. Stop the online command.
2. Change the mode.
14.26 : Illegal command,SERVICE mode
Code
: &H0E1A
Meaning/Cause
: Unable to execute since operation is in SERVICE mode.
Action
: 1. Cancel SERVICE mode.
2. Change the exclusive control settings so it can be used in
SERVICE mode.
14.31 : Illegal port type
Code
: &H0E1F
Meaning/Cause
: Communication port not specified.
Action
: Contact our company with details on this problem.
[15] Memory card errors
15.1 : Invalid file attribute
Code
: &H0F01
Meaning/Cause
: a. Directory was accessed.
b. Read/write protected file was accessed.
Action
: 1. Change to a file which can be accessed.
2. Change to a file allowing read/write.
Summary of Contents for RCX40
Page 1: ...User s Manual ENGLISH E YAMAHA 4 AXIS ROBOT CONTROLLER E75 Ver 12 00 RCX40 ...
Page 2: ......
Page 16: ...viii MEMO ...
Page 18: ...MEMO ...
Page 24: ...1 6 MEMO ...
Page 26: ...MEMO ...
Page 34: ...MEMO ...
Page 284: ...MEMO ...
Page 308: ...5 24 MEMO ...
Page 310: ...MEMO ...
Page 318: ...6 8 MEMO ...
Page 320: ...MEMO ...
Page 328: ...7 8 MEMO ...
Page 330: ...MEMO ...
Page 336: ...MEMO ...