4-
172
Operation
4
12. “SYSTEM” mode
c
CAUTION
This function is enabled from V8.23
or later.
8. DI noise filter/SCANMD
This parameter cancels external input signals in the form of short pulses such as noise
pulses (misdetected as dedicated input signals or general-purpose input signals). This
is effective in preventing response to unnecessary input.
When this parameter is enabled, no response will be made to input signals with a
pulse width of less than 25 msec. Therefore, the ON or OFF signal width for dedicated
input signals and general-purpose input signals must be longer than 25 msec.
[Procedure]
1) Select “8. DI noise filter" in "SYSTEM>PARAM>OTHERS" mode.
2) Press the
F 1
(EDIT) key.
The function key menu changes.
Fig. 4-12-38 Setting “DI noise filter"
SYSTEM
>PARAM>OTHER V8.23
4.DO cond. on EMG
HOLD
5.Watch on STD.DO DC24V
VALID
6.Incremental Mode control
INVALID
7.IO cmd (DI05) on STD.DIO
INVALID
8.DI noise filter
VALID
INVALID
VALID
3) Press the
F 1
(INVALID) or
F 2
(VALID) key.
4) Press the
ESC
key to quit the edit mode.