12. “SYSTEM” mode
2. Data display length/DATLEN
This parameter sets the number of digits to display such as for point data. This is
automatically set to “6char” (6 digits) when the parameters are initialized.
[Procedure]
1) Select “2. Data display length” in “SYSTEM>PARAM>OTHERS” mode.
2) Press the
F 1
(EDIT) key.
The function key menu changes.
Fig. 4-12-32 Setting the “Data display length”
SYSTEM
>PARAM>OTHER V8.01
1.Display language(JPN/ENG)
ENGLISH
2.Data display length
6char
3.Parameter display unit
PULSE
4.DO cond. on EMG
HOLD
5.Watch on STD.DO DC24V
VALID
6char
8char
3) Press the
F 1
(6char) or
F 2
(8char) key.
4) Press the
ESC
key to quit the edit mode.
3. Parameter display unit/PDUNIT
This parameter sets the units for showing axis parameters. This is automatically set to
“pulses” when the parameters are initialized.
[Procedure]
1) Select “3. Parameter display units” in “SYSTEM>PARAM>OTHERS” mode.
2) Press the
F 1
(EDIT) key.
The function key menu changes.
Fig. 4-12-33 Setting the parameter display units
SYSTEM
>PARAM>OTHER V8.01
1.Display language(JPN/ENG)
ENGLISH
2.Data display length
6char
3.Parameter display unit
PULSE
4.DO cond. on EMG
HOLD
5.Watch on STD.DO DC24V
VALID
PULSE
MM/DEG
3) Press the
F 1
(PULSE) or
F 2
(MM/DEG) key.
4) Press the
ESC
key to quit the edit mode.
Summary of Contents for RCX40
Page 1: ...User s Manual ENGLISH E YAMAHA 4 AXIS ROBOT CONTROLLER E75 Ver 12 00 RCX40 ...
Page 2: ......
Page 16: ...viii MEMO ...
Page 18: ...MEMO ...
Page 24: ...1 6 MEMO ...
Page 26: ...MEMO ...
Page 34: ...MEMO ...
Page 284: ...MEMO ...
Page 308: ...5 24 MEMO ...
Page 310: ...MEMO ...
Page 318: ...6 8 MEMO ...
Page 320: ...MEMO ...
Page 328: ...7 8 MEMO ...
Page 330: ...MEMO ...
Page 336: ...MEMO ...