6/98
Xerox DocuPrint N17 Service Manual
7-107
Repair Analysis Procedures (RAPs)
7.5.21 Resolution
Definition
At 600 DPI, two pixel lines and halftone patches cannot be reproduced
clearly on the print. See
Figure 7.5.2.2 System Controller Test Print
Pattern Legend.
Initial Action:
•
Ensure the resolution is set to 600 DPI in the System Menu (5.1.4.7 System Menu).
•
Ensure that the print density is set to the default value (3). Execute Diagnostic Mode 3, Print
Density.
Procedure:
1 Replace the EP Cartridge. The problem is resolved.
Y: Return to Final Actions.
N: Replace the following in sequence to resolve the problem:
- Laser Assembly
- High Voltage Power Supply (HVPS)
NOTE: After problem is resolved, reinstall the old EP Cartridge.