![background image](http://html1.mh-extra.com/html/xerox/docuprint-n17/docuprint-n17_service-manual_4131577159.webp)
3/99
Xerox DocuPrint N17 Service Manual
5-45
General Procedures/Information
5.2.1.16 Exit Motor CCW (Counter Clockwise) Operation
This diagnostic tests the Exit Motor counterclockwise function.
Execute Exit Motor CCW Operation:
1 Enter Diagnostics Mode 1.
The LCD displays PRINT COUNTER OPERATION indicating the
printer is in Diagnostics Mode 1.
2 Press the MENU UP (1) or MENU DOWN (5) key until the LCD displays the EXIT MOTOR-CWW
OPERATION message.
3 Press the ENTER key to execute the test. The LCD displays the EXIT MOTOR-CWW
OPERATION message.
4 Verify that each time the ENTER key is pressed the Exit Motor rotates counter clockwise.
5 If you wish to exit this test and enter another test use the MENU UP (1) or MENU DOWN (5) key
to scroll to another test.
6 To exit this test and return to normal operation, switch OFF the printer power then switch it ON.
EXIT MOTOR-CCW
Operation EXECED
www.printcopy.info