![background image](http://html1.mh-extra.com/html/xerox/docuprint-n17/docuprint-n17_service-manual_4131577302.webp)
6/98
Repair Analysis Procedures (RAPs)
7-52
Xerox DocuPrint N17 Service Manual
7.4.10 Exit Sensor Assembly Failure
1 There is +5VDC between P2-7 and P2-4.
Y: Go to step 6.
N: Go to step 2.
2 There is +5VDC between P/J116-7 and P/J116-11.
Y: Replace the Fuser PWB.
N: Go to step 3.
3 There is +5VDC between P/J115-6 and P/J115-2.
Y: Replace the Fuser Harness.
N: Go to step 4.
4 There is +5VDC between P/J111-A4 and P/J111-A3.
Y: Replace the HVPS.
N: Go to step 5.
5 There is +5VDC between P/J15-A9 and P/J15-A10.
Y: Replace the HVPS Harness.
N: Go to
RAP 7.4.5 Low Voltage Power Supply (LVPS) Assembly Failure (+5VDC).
6 The voltage between P/J2-6 and P/J2-4 is at a low logic level (0VDC) when the sensor detects a
piece of paper and at a high logic level (+5VDC) when not.
Y: Go to step 7.
N: Replace the Fuser Assembly.
7 The voltage between P/J116-6 and P/J116-11 is at 0VDC.
Y: Go to step 8.
N: Replace the Fuser PWB.
8 The voltage between P/J115-7 and P/J115-2 is 0VDC.
Y: Go to step 9.
N: Replace the Fuser Harness.
9 The voltage between P/J111-B5 and P/J111-A3 is 0VDC.
Y: Go to step 10.
N: Replace the HVPS.
10 The voltage between P/J15-B8 and P/J15-A10 is 0VDC.
Y: Replace the Print Engine Controller.
N: Replace the HVPS Harness.
www.printcopy.info
www.printcopy.info