![background image](http://html1.mh-extra.com/html/xerox/docuprint-n17/docuprint-n17_service-manual_4131577533.webp)
6/98
Xerox DocuPrint N17 Service Manual
12-15
High Capacity Feeder Option
12.3.5 Controller PWB
Removal
1. Disconnect the AC Power Cord from the High Capacity Feeder.
2. Remove the four screws that secure the Rear Access Cover. Remove the access cover.
3. Disconnect 8 connectors (J1, J2, J3, J4, J5, J7, J8, and J9) from the Feeder Controller PWB (Figure
4. Remove the screw that secures the lower corner of the Controller PWB and gently lift the PWB off of
the three support posts on the chassis (Figure 12.3.5.1).
Figure 12.3.5.1 Controller PWB
Replacement
1. Perform the removal steps in reverse order.
J6
J5
J4
J3
J8
J9
J2
J1
J7
3
4
rep_05
www.printcopy.info
www.printcopy.info