![background image](http://html1.mh-extra.com/html/xerox/docuprint-n17/docuprint-n17_service-manual_4131577152.webp)
3/99
General Procedures/Information
5-38
Xerox DocuPrint N17 Service Manual
5.2.1.9 Confirm Envelope Solenoid Operation
This diagnostic tests Envelope Tray Feed Solenoid function.
Execute Confirm Envelope Solenoid Operation:
1 Enter Diagnostics Mode 1.
The LCD displays PRINT COUNTER OPERATION indicating the
printer is in Diagnostics Mode 1.
2 Press the MENU UP (1) or MENU DOWN (5) key until the LCD displays the
CONFIRM
ENVELOPE SOLENOID OPERA. message
.
3 Press the ENTER key to start the test. The LCD displays the CONFIRM ENVELOPE message.
4 Verify that when you press the ENTER key, the Envelope Tray Feed Solenoid energizes
momentarily.
5 If you wish to exit this test and enter another test use the MENU UP (1) or MENU DOWN (5) key
to scroll to another test.
6 To exit this test and return to normal operation, switch OFF the printer power then switch it ON.
CONFIRM ENVELOPE
Operation EXECED
www.printcopy.info