![background image](http://html1.mh-extra.com/html/xerox/docuprint-n17/docuprint-n17_service-manual_4131577235.webp)
6/98
Xerox DocuPrint N17 Service Manual
6-39
Wiring Data
13. MCU
↔
MAIN MOTOR
The Main Motor also rotates in the following conditions:
1) When the power is turned on (boom operation): 1 second
2) When the cover is closed after a paper jam is cleared (boom operation and erase cycle): 1 sec.
(Boom operation) + 2.4 sec. (Erase cycle) = 3.4 sec.
Signal Name
Description
/MOT READY
Signal for detecting a problem in the Main Motor (LOW level when
the motor is normal, and HIGH level when the motor is abnormal)
/MAIN MOT ON Signal for switching on and off the Main Motor (LOW level when
switching on the motor, and HIGH level when switching off the motor)
P14
Signal Name
Signal Direction
MO: Main
Motor
M: MCU
Trigger
HIGH
Level
LOW
Level
5
/MOT READY MO
→
M
Level
TTL
TTL
6
/MAIN MOT
ON
MO
←
M
Level
TTL
TTL
www.printcopy.info
www.printcopy.info