5.2.1.3 Reading Fuser Set Temperature
NOTE: This diagnostic displays the current fuser setting. If you wish to change the fuser setting, you
must enter Diagnostic Mode 3 and perform “Fuser Temp. Adjustment.”
This diagnostic displays the current setting for the fuser temperature. The setting is displayed as a two
digit hexadecimal code. The setting has 16 steps (Table 5.2.1.4).
Execute Reading Fuser Set Temperature:
1 Enter Diagnostics Mode 1. The LCD displays PRINT COUNTER OPERATION indicating the
printer is in Diagnostics Mode 1.
2 Press the MENU UP (1) or MENU DOWN (5) key until the LCD displays READING FUSER SET
TEMPERATURE.
3 Press the ENTER key to start the test. The LCD displays a two-digit temperature code that
corresponds to one of the 16 temperature steps.
4 If you wish to exit this test and enter another test, press the MENU UP (1) or MENU DOWN (5)
key to scroll to another test.
5 To exit this test and return to normal operation, switch OFF the printer power then switch it ON.
READING FUSER
Set Temp = XX