3/99
General Procedures/Information
5-48
Xerox DocuPrint N17 Service Manual
5.2.1.19 Offset Motor CCW (Counter Clockwise) Operation
This diagnostic tests the Offset Motor counter clockwise function.
Execute Offset Motor CCW Operation:
1 Enter Diagnostics Mode 1.
The LCD displays PRINT COUNTER OPERATION indicating the
printer is in Diagnostics Mode 1.
2 Press the MENU UP (1) or MENU DOWN (5) key until the LCD displays
OFFSET MOTOR-CCW
OPERATION
message.
3 Press the ENTER key to execute the test. The LCD displays the OFFSET MOTOR-CCW
message.
4 Verify that the Offset Motor rotates in a Counter Clockwise direction each time ENTER is
pressed.
5 If you wish to exit this test and enter another test use the MENU UP (1) or MENU DOWN (5) key
to scroll to another test.
6 To exit this test and return to normal operation, switch OFF the printer power then switch it ON.
OFFSET MOTOR-CCW
Operation EXECED
www.printcopy.info