5.2.1.15 Exit Motor CW (Clockwise) Operation
This diagnostic tests the Exit Motor clockwise function.
Execute Exit Motor CW Operation:
1 Enter Diagnostics Mode 1.
The LCD displays PRINT COUNTER OPERATION indicating the
printer is in Diagnostics Mode 1.
2 Press the MENU UP (1) or MENU DOWN (5) key until the LCD displays the EXIT MOTOR-CW
OPERATION message
.
3 Press the ENTER key to execute the test. The LCD displays the EXIT MOTOR-CW message.
4 Verify that each time the ENTER key is pressed the Exit Motor rotates clockwise.
5 If you wish to exit this test and enter another test use the MENU UP (1) or MENU DOWN (5) key
to scroll to another test.
6 To exit this test and return to normal operation, switch OFF the printer power then switch it ON.
EXIT MOTOR-CW
Operation EXECED
www.printcopy.info