![background image](http://html1.mh-extra.com/html/xerox/docuprint-n17/docuprint-n17_service-manual_4131577153.webp)
3/99
Xerox DocuPrint N17 Service Manual
5-39
General Procedures/Information
5.2.1.10 Confirm Direction Solenoid Operation
This diagnostic tests the Exit Direction Solenoid function.
Execute Confirm Direction Solenoid Operation:
1 Enter Diagnostics Mode 1.
The LCD displays PRINT COUNTER OPERATION indicating the
printer is in Diagnostics Mode 1.
2 Press the MENU UP (1) or MENU DOWN (5) key until the LCD displays the CONFIRM DIRECT
SOLENOID OPERA. message
.
3 Press the ENTER key to execute the test. The LCD displays the CONFIRM DIRECT OPERA.
message.
4 Verify that the Exit Direction Solenoid energizes momentarily.
NOTE: The Direction Solenoid is physically located in the Offset Catch Tray accessory. This option must
be installed to verify operation of the Exit Direction Solenoid.
5 If you wish to exit this test and enter another test use the MENU UP (1) or MENU DOWN (5) key
to scroll to another test.
6 To exit this test and return to normal operation, switch OFF the printer power then switch it ON.
CONFIRM DIRECT
Operation EXECED
www.printcopy.info