92
OUTMODE
must be a
Gate
,
GATEON
and
GATEOFF
must be set to any SMS text,
GATESMS
must be set to
Enabled
and
SIRENOUT
must be set to
OUT1
.
If you want to define the output reset value (how many seconds later after switching the
output it switches the output back), enter that
OUTHDEL
value for the desired second
value - this is how much time the gate will close after switching!
Then ring (call) the phone number of the SIM card in Easy from your phone:
This sends an
output control
command to close the gate to the device, to which the
"SMS
success!
" you will receive a reply message via SMS and then the text entered earlier than
GATEON
- Eg "
GATE CLOSE
".
If you did not enter a control number in the Access List,
“SMS aborted! Permission
required!
” You will receive an SMS message back.
3. Output control - Switching / controlling external devices
The method of connecting external devices from SMS is the same as described in the
above point, except that the value of
SIRENOUT
can be
OUT2, OUT3
or
OUT4
according
to the desired output number.