63
The output has two operation mode: a mono-stable and a bi-stable. The mode can be
configured by the
OUTHDELx
parameter. It holds on the output until the configured interval,
then it switches off.
When its value is:
•
0 or not defined: it is in bi-stable mode
•
1-
86400 (seconds): it’s in mono
-stable mode.
In mono-stable mode the output will be in standby (the relay contacts are opened) until a
trigger event will be occured. In case of a trigger the output relay will close (shortened), then
after a pre-defined delay interval automatically recovers to stand-by position.
During the delay interval when a trigger comes then the timing will be restarted (e.g. for
restartable mono-stable multivibrator).
In case of parameter value ’0’ the output operates in normal mode, then it will not switch back.
In Bi-stable mode there is no delay. From the opened or closed standing positions the relay
can be switched or changed its position in case affect of the appropriate trigger.
The trigger event can be also for mono-stable and bi-stable modes the
OUTON
and
OUTOFF
command value or ringing (e.g. gate opening).