50
At the
SERVER1
parameter fill the primary IP address of the IP-receiver and the
PORT1
value for the port number. Setup the secondary IP address to the
SERVER2
and its port to
the
PORT2
(if it is also necessary).
Change the
IPPROTO
protocol’s format to
TCP
and the
SWPROTO
communication format
to
Enigma
(E2)
, which means a standard Contact ID protocol. (The
M2M
format means the
modified Contact ID (CID) protocol, which can only be used with the following IP receivers (as
Enigma II
®
, Enigma IP2
®
receivers) remote dispatcher software (as Alarmsys
®
and SIMS
®
software)).
For sending the listed parameter values for the device (regarding the
Selected
coloumn)
–
check the proper selection
–
push the
Write config
button at the bottom of the screen. At
the end of the parameter sending, the device is restarting by using the new settings.
Input line’s
Contact ID settings
For
configuring the input line’s event transmitting let’s open the
GPRS Input Parameters
parameter group, and the program will load the related parameters.
You have to
enable
the
IOGPRS
parameter for transmitting th
e input line’s event and status
changes.