background image

 

66 

 

 
(This 

IxBypass

 parameter / value is not visible in the 

EasyTerm

, therefore you can setup here 

or by SMS command messages with th

e IxBYPASS=0 command for the inputs (where ’x’ is the 

nr. of the input)). 

 

 

 

5.5 Output control and gate opening settings

 

 
In  this  operation  mode the 

device 

is  operating  very  similar  to  the  mode  which  have  been 

described at the Chapter 5.3, but the signaling is not performed to the dispatcher centre. In 
this mode, the cellular network is used for remote control of the output lines, and the GSM 
network is utilized for messaging, for calling. The further settings can be important to check 
or to modify in case of neccessary. 
 

Attention!  The  gate  opening  is  possible  through  the  Input  nr.  1  only.  It  is  not 
possible through the IO-Expansion inputs. 

 
For 

gate opening, controling the output line

 

 to remotely switch by SMS text message or a 

voice call/ringing 

 change the 

OUTMODE 

value to 

Gate

The  output  has  two  operation  mode:  a  mono-stable  and  a  bi-stable.  The  mode  can  be 
configured by the 

OUTHDELx

 parameter. It holds on the output until the configured interval, 

then it switches off.  

Summary of Contents for M2M Easy2s

Page 1: ...M2M Easy2s Security Communicator 2G 3G 4G Installation Guide for PCB v9 x _____________________________________ Doc v 1 53 2021 01 11 ...

Page 2: ...meters necessary for its operation Document Type Installation Guide Document Theme M2M Easy2s Security Communicator v9 x PCB Author Tóth Csaba Horváth Attila Tamás WM Systems LLC Checked by Tóth Zoltán Kim Balázs Horváth Attila Document revision Doc v1 53 Pages 101 Hardver version v9 17 Firmware version V2 1 R08F10 Bootloader version REV 0 95 EasyTerm Software version REV 1 3 5 Document Status Fin...

Page 3: ...a 26 4 4 Terminal window communication messages 28 4 5 Load save configuration 29 4 6 Restarting the device 32 4 7 Reload of factory settings 32 4 8 Set manual arming 33 4 9 Output relay control 34 4 10 Bypass zones 35 5 Configuring the Easy 2 37 5 1 GSM transmitter settings 37 5 2 Setup signaling to Enigma IP receiver SIMS Cloud 40 5 3 Celllar network transmitting settings 47 5 4 Standalone Alarm...

Page 4: ...messages 81 7 1 Authentication command 82 7 2 Query commands 82 7 3 Configuration by SMS messages list of commands 83 7 4 Examples for SMS command parameters 86 7 5 Examples for output control with SMS messages 88 7 6 Examples for output control with GSM call ringing 91 8 Contact ID codes table 93 9 Troubleshooting 96 9 1 A failure codes signed by LEDs 96 9 2 Signing the status and signal strength...

Page 5: ... 1 SIM card tray push insert 2 SMA antenna connector for 2G 3G or LTE antenna depending on the module version SMA M 50 Ohm 3 PWR Power supply connector 8 24VDC 1A alternative battery connection 4 IN1 IN2 connectors for input lines for sensors sabotage detection 1 2 3 4 5 7 8 9 11 6 11 11 11 11 ...

Page 6: ...tput for control the output open a gate for siren 8 ALR Alarm TIP RING input for alarm center s connection simulated analogue phone line 9 PROG micro USB connector for configuration firmware refresh 10 Holes for fastening the PCB into metal safety alarm system s box 11 Expansion board connector use in case of presencre of the Easy2 IO expander 12 IO expansion PCB connects to the Easy2S mainboard t...

Page 7: ...ng the inputs The Easy2S has two input lines IN1 IN2 where sensors can be connected by connecting its wire pairs in accordance with the standard connection method shown below by fixing the blanked cable wire pairs for each input In case of voltage inputs make attention to the order of polarity the assembly must be done according to the inputs line titles on PCB board Take care for the proper posit...

Page 8: ...ntact mode for the related input These settings can be installed by the closing the related jumper pairs besides the input terminal block according to the input line nr titles Jumperable input modes with the JP1 JP2 jumpers Contact mode o The input line jumper pairs approach from the connector side lower two pins must be closed o The ground point of the input lines are common o The wiring of input...

Page 9: ...ice on the photo is configured to contact input mode e g for safety sensors the jumpers are closed by pairs at lower 2 pins position Mode Contact Voltage Not inverted NO Normal Open Inactive mode contact opened Active mode contact closed High active Inactive mode 0 1V Active mode 2 24V Inverted NC Normal Closed Inactive mode contact closed Active mode contact opened Low active Inactive mode 2 24V ...

Page 10: ...bed for the main board The IO expnader inputs can be activated with 2 32V voltage Connecting the relay output One switchable output device can be connected to the relay output OUT of the mainboard according to the next figure Connect the blanked cable wire pair to the OUT title output line s terminal block by sliding the companion piece and inserting the stripped wire pair then fixing the screws T...

Page 11: ...put the ALR LED beside the output indicates the active closed position with the appropriate color light during the operation Installing the IO expansion board optional The Easy2S firmware can handle the IO expander board also extension for 6pcs plus of inputs and 3pcs outputs Therefore for the IO board further parameters are available in the device fiwmrare and they are also configurable by the Ea...

Page 12: ...cation and its status See the detailed description ot STA LED part below below yellow flashing lighting GSM GSM receiving signal strenght Signing the available signal strenght more flashes better signal strength red flashing IN1 Input 1 signal Signs the status of the 1 input line I1INV or IDELAY parameters are applied lights if the input wires are closed active green lighting IN2 Input 2 signal Si...

Page 13: ...t the current operation It twill be active only if the GPRS signal transmission permitted In this case from the beginning of the signal transmission the LED starts to flashing It has 3 operation modes lighting continuously the last GPRS signaling was succesful with 3 second of breaks number of flashing the light interval period is half a seconds failure code see later Turned off GSM operation mode...

Page 14: ...in The device in this status will not continues its initialization the receiving of serial port commands is still active for parametrizing After 5 minutes the device automatically tries to restart the module 4 flashing The device cannot login to the cellular network Error during the network registration After 5 minutes the device restarts the modem and retries 5 flashing the GPRS is allowed GPRSEN...

Page 15: ...DC then the INx LED will light according to the related input OUT Output is active yellow The output active indicator OUT LED shows the status of the primer side of the relay When the output is active the relay pair of wires are closed then the output OUT LED will light MDM RDY Modem stand by red During the inicialization the MDM LED blinks quickly approx twice per seconds When the modem is alread...

Page 16: ...eral conditions Using a 8 24V power supply with adapter 12V DC 1A or using the 12V 24V output of the alarm center and connected to the PWR input of the device In case of substituting the phone line activated SIM card In case of TCP IP based cellular network signal transmitting via the 2G 3G 4G network data SIM card with private APN access There can be differences between the Mobile Operator condit...

Page 17: ...n firmware file can be downloaded from here https www m2mserver com m2m downloads EASY2S_V21R08C02 bin Software installation and configuration options Software and parameter upload options Local software refresh with EasyTerm software on micro USB to USB port Remote software refresh FTP server EasyTerm Local configuration with EasyTerm software configuration file parameter values Remote configurat...

Page 18: ...ights are should not lighting or flashing before continue the following steps 1 Mount a 2G 3G LTE antenna according to the module as it can be seen in the picture to the SMA connector 2 until it sleeves In case of wired antenna place the magnetic antenna to fixed position i fit is possible in vertical direction and polarisation and then connect the antenna cable to the device 2 The SIM card must b...

Page 19: ... alarm input line ALR titled no 8 7 You can setup the operation of the input lines by its jumpers 5 behind the input lines IN1 IN2 The operation mode of the input line can be contact or voltage 8 Connect the 12V 24V DC power by the power chord of the alarm center or by a power adapter 12V DC 1A to the power plug s terminal block no 3 PWR titled Then the device will be under voltage turned on and o...

Page 20: ... configuration parameter settings and it sends data through and life signals through the network periodically For the further LED status signals see the LED signals table When you will notice any different operation of the device check the Problem troubleshooting part of the Chapter nr 9 Warning When your device was already installed check the current firmware version of the device SWVER value in ...

Page 21: ...ool which can be used for firmware refresh and programming the device Execute the file EasyTerm_1_3_5 exe Configuration file Pre defined template configuration file with default settings for the Easy2S Load the file modify the configuration file by the EasyTerm and upload to the device File EASY2_V21R08F_CFG_EN cfg M2M Easy2s Security Communicator Firmware Easy2S v2 1 R08 C02 https www m2mserver c...

Page 22: ...smitter signaling to an Enigma IP Receiver device or into the SIMS Cloud software of the dispatching monitoring center the alarm system is connected to the TIP RING input the device transmits the received Contact ID codes on the enclosed private APN of the mobile network as TCP IP data by the Enigma protocol to an Enigma device or to SIMS Cloud software 3 Stand alone alarm system with GSM transmit...

Page 23: ...ure the parameters there is a predefined configuration file in the downloaded ZIP file of the program which can be loaded on the device as a minimum configuration then modified and sent to the device Changes made on Easy2S can also be saved to a configuration file on a PC for later or group configuration 4 1 Introducing the EasyTerm tool The program starts with the following opening screen Applica...

Page 24: ...ng alarm signals of the connected alarm system through GSM connection If you d like to use it as a TCP IP transmitter via the mobile network or as a standalone alarm system then take consider the value Address and Port number when configure and connect to the device When the device can be seen on the serial port in the Connection window 1 at the Serial Port the application will offer the option to...

Page 25: ...ou want to the field right from the Device IP The port number is 9998 by default To the GPRS Login you have to fill the device IMEI last 5 character you can read copy it from the left side at the IMEI coloumn Note that you can also choose GDSP IP instead of Device IP in case of GDSP SIM Attention You can connect on the cellular network 4G 3G or 2G when the GPRSEN parameter was enabled at the GPRS ...

Page 26: ...signal strength values frequently according to the settings The currently used cellular network connection is also listed e g as 3G When connecting to the GSM network or the mobile network the device checks the entered PIN code and indicates that it was accepter and the entered password if was any In case of a SIM PIN error the device will restart the module In case of an error see Chapter 9 Atten...

Page 27: ...device here Use the Refresh button to update the vital sign of the device anytime If the connected status appears at the Status field it indicates that the connection to the device was successful The disconnected indicates that the device is disconnected and unavailable in which case press the Open button to reconnect or if it still fails to disconnect disconnect and reconnect the USB cable and th...

Page 28: ... the left side of the window is active with the signal strength data and terminal window messages This feature is provided for monitoring checking the Easy 2 current operation without any intervention or configuration change Further details on the Chapter 4 4 When you are attempted to Close the monitoring after all you should click to the Serial Port tab for connecting the device for parameter con...

Page 29: ... at initialization when loading a file or read out or restart the device and when you would like to check the previous messages then turn on the Scroll lock feature which will stop the scrolling Then you are allowed to page up The new messages will be inserted to the end of the lista s usual but the message list will not be scrolled down 4 5 Load save a configuration In the File handling window 4 ...

Page 30: ...and send all default parameters to the device by using the Write config button Further parameter s configuration should be necessary to make after the first parameter write and the reboot of the device which will be automatically initiated In the list at the following coloumns appearing Prg Address parameter Name parameter Value The Value shows the currently configured value for the parameter 5 Th...

Page 31: ...elected coloumn The Only selected option at the bottom of the window assigns that only the selected and marked parameters will be sended when the checkbox is unmarked then all displayed and listed parameters will be sended For sending the parameter s to the device push the Write config button at the bottom of the screen The selected values will be sent to the Easy2 The progress indicator signs the...

Page 32: ...the Terminal window 3 and the field strength and status values will be grayed out and the message Restart device will be displayed The device restarts and then reconnects to the port used at the end of the process As soon as it becomes available the status and field strength values are updated the LED states change to color again 4 7 Reload of factory settings If you have to clear reset the device...

Page 33: ...vice can also be controlled manually by the EasyTerm software One button alarm arming and alarm control In stand alone alarm mode you can manually switch the alarm status of the device with the ON OFF buttons next to ARM The precondition for the stand alone alarm mode without remote monitoring signal is that the value of the OUTMODE parameter must be Alarm At the Status you can see whether the ala...

Page 34: ... Note that the outputs of the IO expander cannot be used for gate opening In this case you can see the status of the gate opening at the OUT title and you can manually control the relay output by the ON OFF buttons which also indicates the status of the output line In addition to the output gate opening settings customers can be added to the Access list where you can limit who can open close the g...

Page 35: ...d disarmed status of the zones IxBypass In addition you can bypass the zone valid for all inputs by pressing the Bypass ON button or enable it Bypass OFF button that is you can turn on the alarm for the inputs In the case of a bypassed zone zone events are not alarmed or feedback the device only transmits them as a general event This can be a useful function for eg SMS notification You can also sp...

Page 36: ...36 be specified in the same way by selecting and listing the IO board inputs drop down parameter group as a result of which the additional inputs are displayed ...

Page 37: ...factory sample configuration CFG file EASY2_V21R08F_CFG_EN cfg file in the EasyTerm package and browse with the Browse button 2 Then send the open configuration to Easy2S using the Write config button 3 Wait for uploading of the default configuration then the device will be restarted 4 Then make the additional settings according to the selected operating mode and one of the following purpose opera...

Page 38: ...ck that it is fine or not If you ve changed one of the listed parameter values then the program will highlight the changed value lines by bold For sending the listed parameter values for the device regarding the Selected coloumn check the proper selection push the Write config button at the bottom of the screen At the end of the parameter sending the device is restarting by using the new settings ...

Page 39: ...will highlight the changed value lines by bold For sending the listed parameter values for the device regarding the Selected coloumn check the proper selection push the Write config button at the bottom of the screen At the end of the parameter sending the device is restarting by using the new settings If you need to add the SIM PIN then open the GPRS Service parameter group and modify the PINCODE...

Page 40: ...ettings Load the factory default CFG file by the Browse button Choose the GPRS Settings parameter group at the Device Type Then the program will load the related parameters Change the GPRSEN value to Enable status for the transmitting via the cellular network At the SFUNCT parameter you can define that the primary or secondary server IP address will be the first in the signaling sequence The BACKU...

Page 41: ...fe signals P603 to the dispatcher center IP receiver if it is supported By enabling it the normal GPS value will be sended If you ve changed one of the listed parameter values then the program will highlight the changed value lines by bold For sending the listed parameter values for the device regarding the Selected coloumn check the proper selection push the Write config button at the bottom of t...

Page 42: ...ues based on the information proven by your mobile service provider In the same case the numbers MCC Mobile Country Code and MNC Mobile Network Code must be entered for the OPERATOR parameter For the international MCC MNC numbers here you will get more information https www mcc mnc com This is useful if you do not want your device to use another network when roaming or only use the network of the ...

Page 43: ...gma IP2 receivers remote dispatcher software as Alarmsys and SIMS software If you ve changed one of the listed parameter values then the program will highlight the changed value lines by bold For sending the listed parameter values for the device regarding the Selected coloumn check the proper selection push the Write config button at the bottom of the screen At the end of the parameter sending th...

Page 44: ...ill load the related parameters All detected and received signals and events of the device s input lines are stored in a puffer with their timestamps where 32 events can be stored temporary by the system These will be transmitted forwarded by the device through GPRS network to the defined address then by the handshake communication reply message the buffered event will be deleted after its transmi...

Page 45: ...or opening sensor must be connected in contact mode the NC and C pins of the sensor must be connected to the Easy2S input poles and the 12V GND must be supplied from the device It is also important that the I1INV or I2INV parameter must be set to Normal Closed NC mode The inputs can also be armed so that the parameters I1ARM and I2ARM are used to be set for to doors in the case of the Alarm state ...

Page 46: ... where the jumpers are closed on the lower 2 pins For sabotage event detection sensor tamper protection the IxEOL parameter can be used for the given input EOL end of line resistor can be configured for open detection tamper detection function This will always generate an alarm if it is Enabled ...

Page 47: ...r side of the screen For further settings please check the chapter 5 7 5 3 Cellular network transmitting settings In this operation mode the Easy2S is transmitting to the dispatcher center s IP address or to the remot dispatching software through cellular network The further settings are recommended to check or modify in case of necessary Load the template CFG file by the Browse button GPRS transm...

Page 48: ... The LFUNIT value is the amount for the LFFREQ in seconds or minutes By disabling the LFPRES value you can send hidden life signals P603 to the dispatcher center IP receiver if it is supported By enabling it the normal GPS value will be sended For sending the listed parameter values for the device regarding the Selected coloumn check the proper selection push the Write config button at the bottom ...

Page 49: ...rmation proven by your mobile service provider When you would like to use a DNS or DDNS server you can allow it by the DNS1 DNS2 parameters in the next format e g wmsupport dyndns org Then open the IP GPRS Service parameter group and the program will load the related parameters ...

Page 50: ...g IP receivers as Enigma II Enigma IP2 receivers remote dispatcher software as Alarmsys and SIMS software For sending the listed parameter values for the device regarding the Selected coloumn check the proper selection push the Write config button at the bottom of the screen At the end of the parameter sending the device is restarting by using the new settings Input line s Contact ID settings For ...

Page 51: ... the parameter sending the device is restarting by using the new settings Input settings For configuring the input lines operation open the Input Settings parameter group and the program will load the related parameters The device on its input lines it is capable of generating Contact ID codes and transmitting them through wireless network SMS notification in case of change when ascending the sign...

Page 52: ...ected The IxARM parameter is for granting that the current input line can transmit signal only in Armed status value is Armed or whether it is useful to transmit every status changes even in Disarmed status value is 24 hours The armed value is used for window door detectors sensors by classic the 24 hours arming is capable of protecting the secured zones as protecting the front door in night mode ...

Page 53: ... settings Notification sending settings For the alarm notification and messaging settings open the Notification Parameters parameter group and the program will load the related parameters TELx notification Phone SMS can be setup for max 4 phone numbers Configure at least one number e g TEL1 for SMS notifiction The phone nr syntax must be added in ccpp1234567 format where a positivel prefix and the...

Page 54: ... SMS text here While the IxOFF is active when the level is descending value from high low when the alarm event will be ended when the event will be recovered Define the status recovery disarmed state SMS text here SMSFWD forwarding only messages in SMS text messages to the phone number 1 the mobile provider SMS notifications and SMS commands will be not forwarded ISABEVENT in case of a sabotage ev...

Page 55: ...L defines the recovery time for the output the siren will be turned off muted after this defined interval For alarm system arming or disarming applying the bark sound can enabled by the SIRENBARK parameter The output has two operation mode a mono stable and a bi stable The mode can be configured by the OUTHDELx parameter It holds on the output until the configured interval then it switches off Whe...

Page 56: ...r event can be also for mono stable and bi stable modes the OUTON and OUTOFF command value or ringing e g gate opening For sending the listed parameter values for the device regarding the Selected coloumn check the proper selection push the Write config button at the bottom of the screen At the end of the parameter sending the device is restarting by using the new settings IO expansion settings fo...

Page 57: ...button at the bottom of the screen At the end of the parameter sending the device is restarting by using the new settings 5 4 Standalone Alarming mode SMS notification In this operation mode the Easy 2 is operating as a standalone alarm system when it is transmitting alarms events signal or status changes to a remote IP address through GPRS The further settings are recommended to check or modify i...

Page 58: ...r in night mode If you want to be notified about sensor sabotage events as cable cut etc then configure the I1EOL for the input nr 1 and the I2EOL parameter for the input nr 2 to Enabled value You can enable the ARMSMS parameter which notifies about the remote arm disarm events The ARMON and ARMOFF parameters are for defining the SMS notification messages for the arming on and arming off events Th...

Page 59: ...f an incoming event signal call the pre defined phone number s It is working together with the CALLBARTIME1 and CALLBARTIME2 and CALLTOKENS parameters regarding its values For sending the listed parameter values for the device regarding the Selected coloumn check the proper selection push the Write config button at the bottom of the screen At the end of the parameter sending the device is restarti...

Page 60: ...meter to a shorter time e g 60 or 10 value Notification sending settings For the alarm notification and messaging settings open the Notification Parameters parameter group and the program will load the related parameters Here you can define values only for the input line nr 1 and 2 The IO expansion settings will be listed later at the External IO parameter group TELx notification Phone SMS can be ...

Page 61: ...inging notification It can be defined by the IxS parameter that in case of input status changes for which phone numbers must the device sending SMS text message notification Choose one from the possible notification sequence combinations The IxV is operating quite similar but it is useful for ring notification You can configure that which phone numbers must the device ringin gin case of input line...

Page 62: ...d SMS commands will be not forwarded For sending the listed parameter values for the device regarding the Selected coloumn check the proper selection push the Write config button at the bottom of the screen At the end of the parameter sending the device is restarting by using the new settings Output Siren operation settings For configuring the siren bark and output operation open the Output Settin...

Page 63: ...output relay will close shortened then after a pre defined delay interval automatically recovers to stand by position During the delay interval when a trigger comes then the timing will be restarted e g for restartable mono stable multivibrator In case of parameter value 0 the output operates in normal mode then it will not switch back In Bi stable mode there is no delay From the opened or closed ...

Page 64: ...d C pins of the sensor must be wired to the device s input pole The 12V DC power and GND must be connected from the device It is important to configure the Normal Closed NC mode at the I1INV or I2INV parameters The picture shows the input jumpers configured to contact mode for property safety sensors where the jumpers are closed on the lower 2 pins The inputs can also be armed so that the paramete...

Page 65: ...function This will always generate an alarm if it is Enabled In case of wiring tamper or sensor sabotage the T2 point of the sensor must be connected to the terminal of the Easy2S input the T1 terminal of the sensor to the NC wire and the C wireto the positive wire terminal of the devic s input Important It is highly important to turn off the Bypass feature for the inputs that the events can be si...

Page 66: ...network is used for remote control of the output lines and the GSM network is utilized for messaging for calling The further settings can be important to check or to modify in case of neccessary Attention The gate opening is possible through the Input nr 1 only It is not possible through the IO Expansion inputs For gate opening controling the output line to remotely switch by SMS text message or a...

Page 67: ...ed delay interval automatically recovers to stand by position During the delay interval when a trigger comes then the timing will be restarted e g for restartable mono stable multivibrator In case of parameter value 0 the output operates in normal mode then it will not switch back In Bi stable mode there is no delay From the opened or closed standing positions the relay can be switched or changed ...

Page 68: ...ndling the contact list for output control and gate opening The output and gate control settings can be found in the Configuration file window 4 at the Access List tab You can define phone call numbers max 125 which are allowed to remotely control the output line or the connected device or gate opening system The device will be control its output line only due to the received command SMS text mess...

Page 69: ...ile with ACL file extension to your computer The Load file restores the saved list from your computer to the EasyTerm Attention The Only selected feature is attempted to perform operations only for the selected phone numbers When you will not check this box the operation is valid for the complete list be careful When you already had multiple phone numbers in your contact list then you are attempte...

Page 70: ...ng system When the alarm feature was activated Configuration Output settings OUTMODE Alarm then the armin status can be checked with the ARM ON OFF status and here you can arm the alarm system by the ON button or disarm by the OFF button Important Over the manual control these features can be remotely controlled via SMS text messages and initiating a voice call ringing Attention You cannot use the...

Page 71: ... is not able to send a response acknowledge to an incoming alarm event this can be helpful to apply You can use this feature only for your own risk The STARTUPCID parameter allows the immediate status sending and signaling when the device starting up When it is enabled then in case of a restart or turning off the Easy2 will automatically sends the restart status e g CID code E901 Restart by softwa...

Page 72: ... version select the Firmware update tab from the Configuration Load window 4 Before uploading make sure that the SW VER software version in the Identifier window 2 is older than the version of the file you want to upload It is possible to upload the firmware via a serial port if connected via Serial Port or TCP IP if connected via TCP IP GPRS This is handled automatically by the program The system...

Page 73: ...monitor the progress of the installation with the progress indicator during start upload and status messages When the download starts the message Wait for bootloader will appear followed by Sending file please wait message The installation takes approximately 2 3 minutes to load PLEASE DO NOT STOP the operation of the device during the firmware update DO NOT DISCONNECT THE POWER TO THE DEVICE duri...

Page 74: ...during full loading so do not switch away from the window During the update the device has only limited functionality it does not receive alarm signals does not signal incoming events to its input does not send a life signal and does not process incoming SMS ...

Page 75: ...To connect open the Open button under the Serial Port tab in window 1 wait for it to connect to the device and check the software version for SW VER The device will continue to operate with the new firmware and standard communication messages will be displayed This completes the firmware update process If you are installing from an ftp server In the Firmware update window on the right side of the ...

Page 76: ...buted for one or multiply devices The ftp server usage prequisite is for the device to access the ftp server IP address through the mobile network By the FTPSERVER parameter you can define the ftp server IP address Where the FTPPORT means the server port number by default it is equal to port 21 You have to add the BIN firmware file path and filename to the FTPFILE parameter The FTPUN is the userna...

Page 77: ...77 text message for case of successful installation by FTPSUCC parameter and for case of failure FTPFAIL parameter ...

Page 78: ...the data The other server will be used as backup The order of the primary and secondary server operation can be defined by the SFUNCT parameter The device switches from the primary to the secondary server when the primary server cannot transmit data If the secondary server will successfully receiving the data then the data will be still sent for more 5 seconds to this server Every signal transmitt...

Page 79: ...s the last dialed phone number in the SYSL parameter When the SYS1 parameter is not configured then the Easy 2 will dial the last called number which were called by the alarm system and reads the number from this SYSL parameter When either the SYS1 nor the SYSL parameters are not defined then the device is unable to signaling 6 4 Receiving the signaling of events The device can receive events from...

Page 80: ... The ringing of the active phone numbers will be performed by index number sequence regardless of which input has been activated for a specific number A call notification can be set with the IxV parameter and with IVSMS a call notification that takes effect in the event of a failed SMS notification If the ring is successful the additional phone numbers for the input will not be dialed The ringing ...

Page 81: ...er and divide of the commands is possible with comma sign without a space character The parameter value after the character can be empty You cannot use any of the commands or responses as OK or NO or ERROR for parameter values Query commands You can send several query commands in the same SMS text message but cannot mixed with further value added commands You will receive a response SMS text notif...

Page 82: ...become active only after reboot After sending the last parametring message a couple of minutes later you will receive a response from the device that how many parameters were processed 7 1 Authentication command In every SMS message you have to define the password at the first command position E g PW Command Description PW Connection authentication password PWNEW Password change adding the new pas...

Page 83: ...message order sequence voice call ringing order sequence will be responsed Containing parameters ACCOUNT SQ TEL1 TEL2 TEL3 TEL4 I1S I2S I1V I2V INFSMS Input SMS notification settings Containing params ACCOUNT SQ I1ON I1OFF I2ON I2OFF INFIP Server connection settings Containing parameters ACCOUNT SQ IMEI IP SERVER1 PORT1 SWPROTO 7 3 Configuration by SMS messages list of commands Here we collected a...

Page 84: ... IP address ftp username and password etc Bypass disabling a zone specific commands The BYPASS parameters can be only executed via SMS commands and also possible to control from the EasyTerm Bypass tab Due to these there is possible to disabling the alarm of the zones By the ARMBLOCK parameter when the BYPASS is enabled for the current zone the device can be armed as well as an alarm system whethe...

Page 85: ...of the phone number in the contact list 1 125 When executing this command the given phone number will be deleted from the contact list OUTON Gate opening in Bi stable mode Relay contact will be closed shortened in Mono stable mode Starts the timing OUTOF or OUTOFF Gate closing in Bi stable mode Relay contact will be opened in Mono stable mode Stops the timing Standalone alarm system specific comma...

Page 86: ... sent one after then the device will get these and processing them in a time order sequence Take consider that the device will be restarted when receiving the RESET command the parameter receiving and restarting the device cuold requre minutes until the configuration will be finished Always wait while the device is be ready for the usage and signaling of the incoming events The parametrisation can...

Page 87: ...ing received signals are converted to Contact ID codes and they are transmitted through the cellular network for the remote dispatcher centre IP address PW ABCD GPRSEN 1 SFUNCT 1 BACKUP 1 LFFREQ 300 LFPRES 1 APN NET SERVE R1 89 133 189 139 PORT1 9999 SERVER2 10 197 251 10 PORT2 8010 IPPROT O TCP SWPROTO 2 PW ABCD IOGPRS 1 I1EVENT 110 I1PART 01 I1ZONE 001 IDELAY 25 I1LHEN 1 I1INV 0 I1ARM 0 TEL1 442...

Page 88: ...TE SMS 1 GATEON GATE ON GATEOFF GATE OFF RESET 7 5 Examples of output control with SMS messages According to the SMS format max You can use 158 characters in a control message If the parameters to be set do not fit in a single SMS message start a new one with the usual PW password entry in the first place of each message and then continue with the additional parameters Each message can be sent one...

Page 89: ...g an alarm To do this it must be set in advance In the Access List the phone number from which Easy2s can receive an output control SMS command must be added OUTMODE must be configured to Disarmed value any SMS text must be set for the GATEON and GATEOFF parameters GATESMS must be set to Enabled and SIRENOUT must be set to None Then send an SMS from your phone to the following control SMS to the p...

Page 90: ...If you did not enter a control number in the Access List SMS aborted Permission required You will receive an SMS message back 4 Output control Gate closing To do this it must be set in advance In the Access List the phone number from which Easy2s can receive an output control SMS command must be added OUTMODE must be a Gate GATEON and GATEOFF must be set to any SMS text GATESMS must be set to Enab...

Page 91: ... to define the output reset value how many seconds later after switching the output it switches the output back enter that OUTHDEL value for the desired second value this is how much time the gate will close after switching Then ring call the phone number of the SIM card in Easy from your phone This sends an output control command to open the gate to the device to which the SMS success you will re...

Page 92: ... the SIM card in Easy from your phone This sends an output control command to close the gate to the device to which the SMS success you will receive a reply message via SMS and then the text entered earlier than GATEON Eg GATE CLOSE If you did not enter a control number in the Access List SMS aborted Permission required You will receive an SMS message back 3 Output control Switching controlling ex...

Page 93: ...tage recovery 3141 Ftp firmware update started 1991 Ftp firmware update succesfully finished 1992 Ftp firmware update in progress 1993 1 Device start in case of hw startup restart by software Parameter Description STARTUPCID When the parameter is enabled then in case of restart or hw startup the Easy2 will sending the reason of the start by automatically CID code E901 Restart CID code E900 HW star...

Page 94: ...or dispatcher centre Parameter Description In the Easyterm in case of the LOGOFF command will be sent before the EXIT or EXITCFG commands the it generates a CID code There the zone value shows the interface where the logout from the programming mode were attempted CID code E628 Partition 99 Zone TCP 0x20 Serial 0x30 5 Contact ID message sending after sucessful unsucessful configuration Description...

Page 95: ...ng trial with a bad password Description The password required to connect and configure the device is monitored by the device this is also true for the local serial port EasyTerm TCP connection and SMS for the configuration command or message sent in the command If an incorrect password is entered the device generates a special CID message and transmits the corresponding fixed CID code This is a s...

Page 96: ...sly or flashing slowly the SIM card is not inserted properly Kérjük hogy ellenőrizze a SIM kártya behelyezését vagy helyezze be újra a foglalatba Remove the SIM card then insert it again Please check that you ve inserted the SIM card properly into the device 3 The STA LED is flashing continuously APN failure or wrong APN name or unavailable IP address The GSM network connection was not performed s...

Page 97: ... in the Connection window 1 by the Close button and remove the serial connection from the computer side Then reconnect the cable and push on the Open button If you ve received the Login Failed message in the Terminal window 3 several times then repeat these all above In the next possible failure status cases you can found some examples about the operation malfunction and failure status The figures...

Page 98: ... outage or providing trouble and the GSM state is not available wait for a couple of minutes and push on the Restart device button for the device restart Then please check the network connection and status again GSM module failure When there is no available IMEI identifier and you will receive the null values and the Status is connected then the module has been malcuntioned recheck the operation a...

Page 99: ...99 No SIM card presented or wrong SIM When there is no available SIM ICC identifier Turn off the device and check the proper SIM card insertion and start the device Reconnect and check the settings ...

Page 100: ...ce you can contact us in the following ways Email support m2mserver com Telephone 36 20 333 1111 10 1 Support help For identifying the device please use the sticker on the PCB which contains important information to the support staff ATTENTION The product sticker removal causes loss of the warranty ...

Page 101: ...uct documentation and software can be downloaded from the product website by following this link https m2mserver com en product wireless safety transmitter Online product support can be requested here https m2mserver com en support ...

Page 102: ...ource The pictures in the user guide are only for illustration purposes WM Systems LLC does not acknowledge or accept responsibility for any mistakes in the information contained in the user guide The published information in this document is subject to change without notice All data contained in the user guide is for information purposes only For further information please contact our colleagues ...

Reviews: