In mono-stable mode the output will be in standby (the relay contacts are opened) until a
trigger event will be occured. In case of a trigger the output relay will close (shortened), then
after a pre-defined delay interval automatically recovers to stand-by position.
During the delay interval when a trigger comes then the timing will be restarted (e.g. for
restartable mono-stable multivibrator).
In case of parameter value ’0’ the output operates in normal mode, then it will not switch back.
In Bi-stable mode there is no delay. From the opened or closed standing positions the relay
can be switched or changed its position in case affect of the appropriate trigger.
The trigger event can be also for mono-stable and bi-stable modes the
OUTON
and
OUTOFF
command value or ringing (e.g. gate opening).
For sending the listed parameter values for the device (regarding the
Selected
coloumn)
–
check the proper selection
–
push the
Write config
button at the bottom of the screen. At
the end of the parameter sending, the device is restarting by using the new settings.
IO-expansion settings (for input lines nr. #3-8, and output lines nr. #2-4)
For configuring the parameters of the
IO-expansion
open the
External IO
parameter
group
and the program will load the related parameters.
The listed input parameters starting by the
character „I”
are value for the
input
numbers
from #3 to #8 - according the requirements.
The ’
x
’ assigns the number of the current input/output line.
The listed output parameters starting by the
charact
er „O”
are value for the
output
numbers
from #2 to #4.