The output control is deactivated in this mode by default, then setup the
OUTMODE
value to
Arm/Disarm
value.
If you are attempted to use and switch the siren then allow the input line alarm event to the
siren by the
SIRENOUT
parameter (in case of alerting, the siren will be turned on). The
SIRENDEL
defines the recovery time for the output (the siren will be turned off (muted) after
this defined interval).
For alarm system
arming or disarming
applying the „
bark”
sound can
enabled
by the
SIRENBARK
parameter.
The output has two operation mode: a mono-stable and a bi-stable. The mode can be
configured by the
OUTHDELx
parameter. It holds on the output until the configured interval,
then it switches off.
When its value is:
•
0 or not defined: it is in bi-stable mode
•
1-
86400 (seconds): it’s in mono
-stable mode.