6
5
–
Jumpers for handling the the input lines (IN1, IN2). You can select the following
operation modes:
•
galvanically splitted, independent voltage input lines
•
contact input (detection of wire cut (by using a
10kΩ
EOL resistor) or short)
6
–
Status LEDs
7
–
OUT: relay output (for control the output
–
open a gate, for siren)
8
–
ALR: Alarm TIP RING input (for alarm center
’s
connection)
–
simulated analogue phone
line
9
–
PROG: micro-USB connector (for configuration, firmware refresh)
10
–
Holes for fastening the PCB (into metal safety alarm system’s box)
11
–
Expansion board connector (use in case of presencre of the
Easy2 IO
expander)
12
–
IO-expansion PCB (connects to the Easy2S mainboard through the no. 11 connector)
13
–
Easy2S PCB mainboard
12
13