19
(If it
’s
needed you can remove the card by pushing the SIM
–
but
only
after you’ve
turned
off the device!
)
4.
Wire the required inputs
–
e.g. use them for connecting sensors
–
by wiring the cables pairs to
the input terminal block (4) (
IN1
,
IN2
) as it was already described before.
It is possible to monitoring the devices safety by using the sabotage protection feature: connect
the cables of the magnetic switch of the safety box’s
cover (detection of opening) to the input
line of the
Easy2S
.
5.
Wire the cable pair of the switchable external device to the
OUT
titled input terminal block (7)
connector. You can connect a siren or gate opening circuit or key switch to the output line.
6.
If you would like to use the device as an alarm center signal transmitter (as it is operating by
default), then connect the alarm center to the alarm input line (
ALR
titled) (no. 8).
7.
You can setup the operation of the input lines by its jumpers (5) behind the input lines (
IN1
,
IN2
). The operation mode of the input line can be contact or voltage.
8.
Connect the 12V/24V DC power by the power chord of the alarm center (or by a power adapter
(12V DC 1A)
to the power plug’s terminal block
(no. 3. -
PWR
titled).
Then the device will be under voltage, turned on and operating. The LEDs (6) are flashing
according the current operation
–
as listed in chapter 2.2.
By default the device is operating as a GSM/2G-3G-4G alam center signal transmitter. (You can
reconfigure the device for different operation mode).
2.2 Turning on the device
After starting the
Easy2S
®
,
ca. 40-50 seconds are required from to the operate on the cellular
netwirk, which will be signed by the status LEDs according to the following sequence.
•
When the power voltage added, the devices turns on. The
PWR LED
continuously lighting
by
green
.
•
If the input(s) are wired then the
IN1, IN2 LEDs
are continuously lighting by
green
.