For sending the listed parameter values for the device (regarding the
Selected
coloumn)
–
check the proper selection
–
push the
Write config
button at the bottom of the screen. At
the end of the parameter sending, the device is restarting by using the new settings.
Settings for safety sensors:
The
PIR
(movement detection) sensor and
door opening
sensor must be wired in contact mode
(the
NC
and
C
pins of the sensor must be wired to the device’s input
- / + pole. The +12V DC
power and GND must be connected from the device). It is important to configure the
Normal
Closed (NC)
mode at the
I1INV
or
I2INV
parameters.
The picture shows the input jumpers, configured to contact mode
(for property safety sensors), where the jumpers are closed on the lower 2-pins.
The inputs can also be armed, so that the parameters
I1ARM
and
I2ARM
are used to be set
for to doors in the case of the Alarm state, in which case the input can be armed. In this case,
input changes are only detected and signaled when armed.