90
OUTMODE
must be a
Gate
,
GATEON
and
GATEOFF
must be set to any SMS text,
GATESMS
must be set to
Enabled
and
SIRENOUT
must be set to
OUT1
.
If you want to define the output reset value (how many seconds later after switching the
output it switches the output back), enter that
OUTHDEL
value for the desired second value
- this is how much time the gate will close after switching!
Then send an SMS from your phone to the following control SMS to the phone number of the
SIM card:
PW=ABCD,OUTON
This sends the
gate opening
(output control) command to the device, to which the
"SMS
success!"
you will receive a reply message via SMS.
If you did not enter a control number in the
Access List
, “
SMS aborted! Permission
required!
” You will receive an SMS message back.
4. Output control - Gate closing
To do this, it must be set in advance: In the
Access List
,
the phone number from which
Easy2s
®
can receive an output control SMS command must be added.
OUTMODE
must be a
Gate
,
GATEON
and
GATEOFF
must be set to any SMS text,
GATESMS
must be set to
Enabled
and
SIRENOUT
must be set to
OUT1
.
Then send an SMS from your phone to the following control SMS to the phone number of the
SIM card:
PW=ABCD,OUTOFF
This sends the command required to
gate close
(output control) to the device, to which the
"
SMS success
!" you will receive a reply message via SMS.
If you did not enter a control number in the
Access List,
“
SMS aborted! Permission
required!
” You will receive an SMS message back.