94
•
TCP
–
0x20
•
Serial
–
0x30
(3)
Login to Programming mode (for dispatcher centre)
Parameter
Description
-
In the
Easyterm
in case of
password authentication after login, the
following event generates, when the
Easyterm
sends the LOGIN
command to the device. The CID code generates with the zone value,
which shows the interface where the login were attempted.
CID code: E627
Partition: 99
Zone:
•
TCP
–
0x20
•
Serial
–
0x30
(4)
Logout from Programming mode (for dispatcher centre)
Parameter
Description
-
In the
Easyterm
in case of
the
LOGOFF
command will be sent before
the EXIT or EXITCFG commands, the
it
generates a CID code. There,
the zone value shows the interface where the logout from the
programming mode were attempted.
CID code: E628
Partition: 99
Zone:
•
TCP
–
0x20
•
Serial
–
0x30
(5) Contact ID message sending after sucessful / unsucessful configuration
Description
Easyterm sends the CONFIG = X command from the device before configuration. After
configuring the parameters, it generates and signals a special CID message - the
corresponding CID code, whether the configuration was successful or failed.