93
Chapter 8. Contact ID codes (table)
We’ve collected the
Easy 2
special Contact ID codes here into the following tables.
Event
CID code
Alarm by an event - recovery
1407
Alarm by an event
3407
Alarm failure by an event
3454
Login tried by wrong password (2)
1461
Login (3)
1627
Logout (4)
1628
Device startup (1)
–
by hardware
1900
Device restart (1)
–
by software
1901
Sabotage detection on the input line
1141
Sabotage - recovery
3141
Ftp firmware update started
1991
Ftp firmware update succesfully finished
1992
Ftp firmware update in progress
1993
(1)
Device start: in case of hw startup /restart by software
Parameter
Description
STARTUPCID
When the parameter is
enabled
, then in case of restart or hw-startup
the
Easy2
will sending the reason of the start by automatically.
CID code: E901
–
Restart
CID code: E900
–
HW startup
(2)
Attempting to login with wrong password
Parameter
Description
-
The zone value informs about the interface source where the login
where tried to attempted.
CID code: E461
Partition: 99
Zone:
•
SMS
–
0x10