35
4.10 Bypass zones
Open the
Bypass
window at the top right of the screen, scroll down the list and select
Easy2 inputs
parameter group from the list.
As a result, the program reads the set parameters for the zones and the number of detected inputs -
valid for the inputs - from the device.
The reading of the parameters is indicated by a process indicator after the list is selected.
After reading, you can view the input statuses (
State
) and the settings applied to the inputs (such as
Type, H
→
L
(high to low: decreasing edge)
and L
→
H
(low to high: increasing edge), the
Arm type
,
(type of alarm),
EOL
, and the armed / disarmed status of the zones (
IxBypass
).
In addition, you can bypass the zone valid for all inputs (by pressing the
Bypass
ON
button) or enable
it (
Bypass
OFF
button) - that is, you can turn on the alarm for the inputs.
In the case of a bypassed zone, zone events are not alarmed or feedback, the device only
transmits them as a general event. (This can be a useful function for eg SMS notification).
You can also specify this zone bypass for the inputs individually,
I1Bypass
can be set to 1.
input,
I2Bypass
is the 2nd input. means input. The
ON
switch next to it turns it off,
OFF
turns on its alarm status for that zone. (Bypassing and enabling the zone is also possible via
SMS, according to the SMS commands described later.)
In the case of an IO expansion panel, the zone bypass for the additional inputs (No. 3-8) can