41
You can modify the
ACCOUNT
parameter value if you are attempted to signaling an own
customer ID for the identification. If it is not used, the BCDE code will be signaled.
The
LFFREQ
is the life signal sending frequency on GPRS channel, which is setup to 300
seconds by general. Check that it is fine or not. The
LFUNIT
value is the amount for the
LFFREQ
in seconds or minutes.
By
disabling
the
LFPRES
value you can send hidden life signals (P603) to the dispatcher
center/IP-receiver (if it is supported). By
enabling
it, the normal GPS value will be sended.
If
you’ve changed
one of the listed parameter values, then the program will highlight the
changed value lines by
bold
. For sending the listed parameter values for the device (regarding
the
Selected
coloumn)
–
check the proper selection
–
push the
Write config
button at the
bottom of the screen.
The program will indicates the configuration progress by the progress bar at the bottom of the
screen and at the
Terminal window
(3). At the end of the parameter sending, the device is
restarting by using the new settings.