Coding in
the as
delivered
condition
Address:
value
Function mode
Coding
change
Address:
value
Possible change
Summer econ. M2
A5:5
*
1
With heating circuit
pump logic function
A5:0
Without heating circuit
pump logic function
Min. flow temp. A1
C5:20
Electronic limit of the
minimum flow tempera-
ture: 20 °C
C5:1
to
C5:127
Minimum limit adjustable
from 1 to 127 °C
Min. flow temp. M2
C5:20
Electronic limit of the
minimum flow tempera-
ture: 20 °C
C5:1
to
C5:127
Minimum limit adjustable
from 1 to 127 °C
Max. flow temp. A1
C6:75
*
1
Electronic maximum
flow temperature limit at
75 °C
C6:1
to
C6:127
Maximum limit adjustable
from 1 to 127 °C
Max. flow. temp. M2
C6:75
*
1
Electronic maximum
flow temperature limit at
75 °C
C6:1
to
C6:127
Maximum limit adjustable
from 1 to 127 °C
Slope A1
d3:14
*
1
Heating curve slope =
1.4
d3:2
to
d3:35
Heating curve slope
adjustable from 0.2 to 3.5
(see page 33)
Slope M2
d3:14
*
1
Heating curve slope =
1.4
d3:2
to
d3:35
Heating curve slope
adjustable from 0.2 to 3.3
(see page 33)
Level A1
d4:0
*
1
Heating curve level =
0
d4:
–
13
to
d4:40
Heating curve level
adjustable from
–
13 to 40
(see page 33)
Level M2
d4:0
*
1
Heating curve level =
0
d4:
–
13
to
d4:40
Heating curve level
adjustable from
–
13 to 40
(see page 33)
Code 1
(cont.)
41
Coding
56
92
550
GB
*1
Only for weather-compensated control units.
Summary of Contents for VITODENS 300 WB3A
Page 10: ...Opening the control unit housing 10 5862 570 GB...
Page 14: ...Closing control unit housing and inserting user interface 14 5862 570 GB...
Page 129: ...Parts lists cont 113 Parts lists 5692 550 GB...
Page 130: ...Parts lists cont 114 Parts lists 5692 550 GB...
Page 131: ...Parts lists cont 115 Parts lists 5692 550 GB...
Page 132: ...Parts lists cont 116 Parts lists 5692 550 GB...
Page 133: ...Parts lists cont 117 Parts lists 5692 550 GB...
Page 145: ...129 5692 550 GB...
Page 146: ...130 5692 550 GB...
Page 147: ...131 5692 550 GB...