Coding in
the as
delivered
condition
Address:
value
Function mode
Coding
change
Address:
value
Possible change
screed-drying function
has been completed or if
the address is manually
set to 0.
F1:6
to
F1:15
Constant flow tempera-
ture 20 °C
F2:8
*
2
Time limit for party
operation 8 hours or
external operating
mode changeover via
push button
*
3
F2:0
No time limit for party
mode
F2:1
to
F2:12
Time limit adjustable from
1 to 12 hours
*
3
*
3
F5:12
Run-on time of the inter-
nal circulation pump in
heating mode
F5:0
No run-on time of the
internal circulation pump
F5:1
to
F5:20
Run-on time of the inter-
nal circulation pump
adjustable from 1 to
20 minutes
F6:0
*
4
In "DHW only" operat-
ing mode, the internal
circulation pump is per-
manently OFF
F6:1
to
F6:24
In "DHW only" operating
mode, the internal circu-
lation pump will be
started 1 to 24 times per
day for 10 minutes
respectively
F6:25
In "DHW only" operating
mode, the internal circu-
lation pump is perma-
nently ON
F7:0
*
4
In "Standby mode",
the internal circulation
pump is permanently
OFF
F7:0
In "Standby mode", the
internal circulation pump
is permanently OFF
F7:1
to
In "Standby mode", the
internal circulation pump
Code 2
(cont.)
61
Coding
56
92
550
GB
*2
Only for weather-compensated control units.
*3
In heating program
rw
, the party mode ends
automatically
when changing over to
operation with standard room temperature.
*4
Only for constant temperature control units.
Summary of Contents for VITODENS 300 WB3A
Page 10: ...Opening the control unit housing 10 5862 570 GB...
Page 14: ...Closing control unit housing and inserting user interface 14 5862 570 GB...
Page 129: ...Parts lists cont 113 Parts lists 5692 550 GB...
Page 130: ...Parts lists cont 114 Parts lists 5692 550 GB...
Page 131: ...Parts lists cont 115 Parts lists 5692 550 GB...
Page 132: ...Parts lists cont 116 Parts lists 5692 550 GB...
Page 133: ...Parts lists cont 117 Parts lists 5692 550 GB...
Page 145: ...129 5692 550 GB...
Page 146: ...130 5692 550 GB...
Page 147: ...131 5692 550 GB...