Codes
Coding in
the as
delivered
condition
Address:
value
Function mode
Coding
change
Address:
value
Possible change
System design
00:1
System design 1:
1 heating circuit without
mixer A1, without DHW
heating
00:2
System design 1:
1 heating circuit without
mixer A1, with DHW heat-
ing
00:3
System design 2, 4, 5:
1 mixer circuit M2, with-
out DHW heating
00:4
System design 2, 4, 5:
1 mixer circuit M2, with
DHW heating
00:5
System design 3:
1 heating circuit without
mixer A1 and 1 mixer cir-
cuit M2, without DHW
heating
00:6
System design 3:
1 heating circuit without
mixer A1, 1 mixer circuit
M2 with DHW heating
01:1
*
1
Single boiler system
01:2
Multi-boiler system with
Vitotronic 333
Boiler/burner
06:...
Maximum limit of the
boiler water tempera-
ture, defaulted by the
boiler coding card
06:20
to
06:127
Maximum limit of the boi-
ler water temperature
within the ranges
defaulted by the boiler
07:1
*
1
Boiler number in
multi-boiler systems
07:2
to
07:4
Boiler number 2 to 4 in
multi-boiler systems
1E:0
Natural gas operation,
defaulted by the boiler
coding card
1E:1
LPG operation, defaulted
by the boiler coding card
Code 2
(cont.)
43
Coding
56
92
550
GB
*1
Only for constant temperature control units.
Summary of Contents for VITODENS 300 WB3A
Page 10: ...Opening the control unit housing 10 5862 570 GB...
Page 14: ...Closing control unit housing and inserting user interface 14 5862 570 GB...
Page 129: ...Parts lists cont 113 Parts lists 5692 550 GB...
Page 130: ...Parts lists cont 114 Parts lists 5692 550 GB...
Page 131: ...Parts lists cont 115 Parts lists 5692 550 GB...
Page 132: ...Parts lists cont 116 Parts lists 5692 550 GB...
Page 133: ...Parts lists cont 117 Parts lists 5692 550 GB...
Page 145: ...129 5692 550 GB...
Page 146: ...130 5692 550 GB...
Page 147: ...131 5692 550 GB...