Coding in
the as
delivered
condition
Address:
value
Function mode
Coding
change
Address:
value
Possible change
62:2
Circulation pump with 2
minutes run-on time
62:0
Circulation pump without
run-on
62:1
to
62:15
Run-on time adjustable
from 1 to 15 minutes
63:0
*
1
Without auxiliary
function for DHW load-
ing
63:1
Additional function: 1 x
daily
63:2
to
63:14
Every 2 to every 14 days
63:15
2 x daily
65:...
Information regarding
the type of diverter
valve (not adjustable)
65:0
Without diverter valve
65:1
Diverter valve by Viess-
mann
65:2
Diverter valve by Wilo
65:3
Diverter valve by Grund-
fos
67:40
In conjunction with Vito-
solic solar control unit:
Set DHW value 3
67:0
to
67:60
DHW set value adjusta-
ble from 0 to 60 °C
6C:100
Set speed internal DHW
loading pump 100 %
6C:0
to
6C:100
Set speed adjustable
from 0 to 100 %
6F:100
Max. output during
DHW loading 100 %,
defaulted by the boiler
coding card
6F:0
to
6F:100
Max. output during DHW
loading adjustable from 0
to 100 %
71:0
*
2
DHW circulation
pump: On according to
DHW time program
71:1
OFF during DHW loading
to set value 1
71:2
ON during DHW loading
to set value 1
72:0
*
2
DHW circulation
pump: ON according to
time program
72:1
OFF during DHW loading
to set value 2
72:2
ON during DHW loading
to set value 2
Code 2
(cont.)
49
Coding
56
92
550
GB
*1
Only for constant temperature control units.
*2
Only for weather-compensated control units.
Summary of Contents for VITODENS 300 WB3A
Page 10: ...Opening the control unit housing 10 5862 570 GB...
Page 14: ...Closing control unit housing and inserting user interface 14 5862 570 GB...
Page 129: ...Parts lists cont 113 Parts lists 5692 550 GB...
Page 130: ...Parts lists cont 114 Parts lists 5692 550 GB...
Page 131: ...Parts lists cont 115 Parts lists 5692 550 GB...
Page 132: ...Parts lists cont 116 Parts lists 5692 550 GB...
Page 133: ...Parts lists cont 117 Parts lists 5692 550 GB...
Page 145: ...129 5692 550 GB...
Page 146: ...130 5692 550 GB...
Page 147: ...131 5692 550 GB...