C
Vitotrol 100 UTD (only for control
units operating with a constant
temperature)
D
Vitotrol 100 UTA (only for control
units operating with a constant
temperature)
Plug 230 V~
fÖ
Power supply
&
Never interchange cores L1 and
N.
&
Install an isolator in the mains
supply line which simulta-
neously separates all non-
earthed conductors from the
mains with at least 3 mm contact
separation.
&
Max. fuse rating 16 A.
sÖ
Heating circuit pump or boiler cir-
cuit pump
lH
&
Mains supply - accessories
(230 V ~ 50 Hz). Where the boi-
ler is installed in a bathroom or
shower room, the mains supply
of accessories outside the wet
area must not be connected to
the control unit. The power sup-
ply connection for accessories
can be made immediately at the
control unit, if the boiler is
installed outside damp areas.
This connection is directly con-
trolled with the system ON/OFF
switch (max. 4 A).
&
Vitotrol 100 UTA
&
Vitotrol 100 UTD
Low voltage plug
!
Outside temperature sensor
(only for weather-compensated
mode)
Installation
&
North or northwestern wall, 2
to 2.5 m above ground level. In
multi-storey buildings, in the
upper half of the second floor
&
Not above windows, doors or
ventilation outlets
&
Not immediately below balcony
or gutter
&
Do not render over
&
Two core cable with a maxi-
mum length of 35 m and a
cross-section of 1.5 mm
2
?
Flow temperature sensor for low
loss header (accessories)
%
Cylinder temperature sensor
(part of the DHW cylinder con-
nection set).
Connection to cables with plugs
outside of the control unit.
aVG
KM BUS user (accessory)
&
Vitotrol 200 or 300 remote con-
trol
&
Vitocom 100
&
Extension kit for one heating
circuit with mixer
&
Vitosolic
&
External extension H1 or H2
Electrical connections
(cont.)
12
58
62
570
GB
Summary of Contents for VITODENS 300 WB3A
Page 10: ...Opening the control unit housing 10 5862 570 GB...
Page 14: ...Closing control unit housing and inserting user interface 14 5862 570 GB...
Page 129: ...Parts lists cont 113 Parts lists 5692 550 GB...
Page 130: ...Parts lists cont 114 Parts lists 5692 550 GB...
Page 131: ...Parts lists cont 115 Parts lists 5692 550 GB...
Page 132: ...Parts lists cont 116 Parts lists 5692 550 GB...
Page 133: ...Parts lists cont 117 Parts lists 5692 550 GB...
Page 145: ...129 5692 550 GB...
Page 146: ...130 5692 550 GB...
Page 147: ...131 5692 550 GB...