Summary of Contents for PROMAX 24

Page 1: ...romax Store User Guide Condensing Boiler with Integrated Hot Water Storage 24 en United Kingdom Please keep these instructions in a safe place If you move house please hand them over to the next occupier ...

Page 2: ...m or by any means or stored in any retrieval system of any nature including in any database in each case whether electronic mechanical recording or otherwise without the prior written permission of the copyright owner except for permitted fair dealing under Copyrights Designs and Patents Act 1988 Applications for the copyright owner s permission to reproduce or make other use of any part of this p...

Page 3: ...central heating mode Domestic Hot Water Indicator The indicator will illuminate when hot water is being supplied to a tap or shower Burner On Indicator The indicator will illuminate when the burner has fired and is heating your central heating or domestic hot water Boiler Output Temperature In either the central heating or domestic hot water position the display will illuminate showing the current...

Page 4: ...d on Is the display lit Display Central Heating Indicator Domestic Hot Water Indicator Burner On Indicator Boiler operating satisfactorily 2 1 0 4 3 bar Is the Central Heating System Pressure between 1 and 2 5 bar If the reading falls below 1 bar repressurise the system as described in section 3 0 Does the display show an error code e g E133 E110 Boiler not working NO NO YES YES YES NO Turn the ON...

Page 5: ... set high enough 15 10 5 20 2 5 15 10 5 20 2 5 Turn Room Thermostat to maximum setting typical example shown If you don t know what you need to do to get the boiler to light or need help with the system and controls contact your installer as soon as possible YES NO CONTACT YOUR INSTALLER OR SERVICE ENGINEER YES ON M T W T F S S HW CH ADVANCE HW CH CH COPY BOOST ENTER _ SET RUN CLOCK HW PROG CH PRO...

Page 6: ...loop consists of two taps and a separate metal braided hose pipe 4 Only when repressurising should the hose be connected between the two taps No tools are necessary for this but ensure that the wing nuts on the hose pipe ends are tightened onto the taps 5 Fully open one of the taps first and then while watching the pressure gauge carefully open the second tap 6 When the needle on the gauge is indi...

Page 7: ... Safety and Maintenance Fig 4 5 Top 250mm Left side 25mm Right Side 25mm Front 50mm In Operation 450mm For Servicing If your boiler is installed in a compartment do not use it for storage purposes Do not obstruct any purpose provided ventilation openings Flammable materials must not be stored in close proximity to your boiler Avoid skin contact when your boiler is in operation as some surfaces may...

Page 8: ...ler temperature falls below 4 C the boiler will fire until a temperature of 15 C is reached 2 If a system frost thermostat has been fitted your installer will be able to advise you then to operate correctly and protect your system the gas and electricity must be left on and the appliance set in the central heating mode 3 The boiler incorporates an integral pump protection feature which monitors th...

Page 9: ...er Efficiency Regulations 1993 No 3083 and is deemed to meet the requirements of Directive 92 42 EEC on the energy efficiency requirements for new hot water boilers fired with liquid or gaseous fuels Type test for purpose of Regulation 5 certified by Notified Body 0085 Product Production certified by Notified Body 0086 For GB IE only 6 2 Benchmark Commissioning Checklist Please ensure that the ins...

Page 10: ...buttons for inputting time of day ON OFF times etc or as SELECT buttons for using the advance facility and choosing override programme options Figure 7 can be used to identify the SET buttons indicators and symbols 7 3 Setting the Programmer 1 Turn the appliance selector switch to central heating and hot water position 2 Setting Day and Time NOTE When setting the day time of day or switch times if...

Page 11: ... OFF 12 00 pm 1 00 pm 12 00 pm 12 00 pm 3rd ON 3rd OFF 3rd ON 3rd OFF 4 00 pm 11 30 pm 4 30 pm 11 30 pm 2 If these settings do not meet your own requirements then they can be easily changed as follows i Press the SET BUTTON twice so that the SET INDICATOR is in a PROG position HW or CH The display will indicate the day and the DAY OF THE WEEK INDICATOR will now flash ii Use the or BUTTONS to move ...

Page 12: ...e SELECT buttons and indicators 7 6 Programme Selection 1 The following programmes can be selected for either HOT WATER or HEATING or both together AUTO When AUTO is selected the programmer will switch ON and OFF according to the switching times held in the memory ie up to three ON OFF periods per day ALL DAY When ALL DAY is selected the programmer will switch the system on at the 1st ON TIME and ...

Page 13: ...mbled or you wish to revert to the factory pre set programme you can RESET the programmer by pressing the MINUS adjust button and the ENTER HW SELECT BUTTON together see Fig 19 2 After using the RESET procedure you will need to reprogramme the day and time of day plus any changes you wish to make to the factory pre set programme 3 The programmer is not user serviceable DO NOT ATTEMPT TO DISMANTLE ...

Page 14: ...ds that the boiler has been installed and commissioned correctly It can be found at the back of the installation and service manual and should be kept in a safe place for the life of the boiler We will check that the Benchmark Checklist has been completed on an in warranty visit Ways to register your warranty If your boiler is eligible for an extended warranty your installer may register the produ...

Page 15: ...of Gas Safe registered engineers to visit If your product is in warranty everything is free of charge subject to our warranty terms and conditions If it is out of warranty we can still help and offer a range of options you can choose from to suit your needs Contact Baxi Customer Support 0344 871 1525 Opening hours Monday Friday 8 00am 6 00pm Weekends and Bank Holidays 8 30am 2 00pm Please note cal...

Page 16: ...iency class A A B Rated heat output Prated or Psup kW Space heating Annual energy consumption kWh GJ Water heating Annual energy consumption kWh GJ Seasonal space heating energy efficiency Water heating energy efficiency Sound power level LWA indoors dB See For specific precautions about assembling installing and maintaining consult the relevant section as detailed on the Contents page 90 115 150 ...

Page 17: ...y c n e i c fi f e y g r e n e g n i t a e h e c a p s l a n o s a e S e g a k c a p f o y c n e i c fi f e y g r e n e g n i t a e h e c a p s l a n o s a e S R O n i y c n e i c fi f e y g r e n e g n i t a e h e c a p s l a n o s a e S p m u p t a e h y r a t n e m e l p p u S g n i t a r k n a T n i y c n e i c fi f e r o t c e l l o C m n i e m u l o v k n a T m n i e z i s r o t c e l l o C n ...

Page 18: ...ʷ Prated whereby Prated is related to the preferential space heater Weighting of boilers 0 0 0 0 1 0 3 0 37 0 2 0 55 0 70 0 3 0 75 0 85 0 4 0 85 0 94 0 5 0 95 0 98 0 6 0 98 1 00 0 7 1 00 1 00 1 The intermediate values are calculated by linear interpolation between the two adjacent values 2 Prated is related to the preferential space heater or combination heater III IV I V Psup Prated Psup 1 2 II p...

Page 19: ...u e g a k c a p f o y c n e i c fi f e y g r e n e g n i t a e h r e t a W y t i c i r t c e l e y r a i l i x u A n o i t u b i r t n o c r a l o S r e t a e h n o i t a n i b m o c f o y c n e i c fi f e y g r e n e g n i t a e h r e t a W e c i v e d r a l o s f o e h c fi m o r f r e d l o C r e m r a W s n o i t i d n o c e t a m i l c r e m r a w d n a r e d l o c r e d n u y c n e i c fi f e...

Page 20: ...20 10 0 Notes ...

Page 21: ...21 10 0 Notes ...

Page 22: ...22 10 0 Notes ...

Page 23: ...t switches Do not operate any electrical equipment Do not use a telephone in the hazardous area Extinguish any naked flame and do not smoke Open windows and doors in the hazardous area Turn off the gas supply at the meter Warn any other occupants and vacate the premises Telephone the National Gas Emergency Service on 0800 111 999 Faulty boiler If it is known or suspected that a fault exists on the...

Page 24: ...erms and conditions visit www baxi co uk terms Failure to adhere to terms and conditions will void your manufacturer s warranty Baxi Brooks House Coventry Road Warwick CV34 4LL Please ensure the boiler is installed in accordance with these installation instructions and that you adhere to the Building Regulations e oe All descriptions and illustrations provided in this document have been carefully ...