Displayed
fault code
Const.
Weat-
her-
comp.
System
character-
istics
Cause
Remedy
30
X
X
Burner
blocked
Boiler temperature
sensor shorted out
Check the
boiler tem-
perature sen-
sor (see
page 87)
38
X
X
Boiler temperature
sensor lead break
40
X
Mixer
closes
Heating circuit M2
flow temperature
sensor shorted out
Check the
flow tempera-
ture sensor
48
X
Heating circuit M2
flow temperature
sensor lead break
50
X
X
No DHW
heating
Cylinder tempera-
ture sensor shorted
out
Check the
cylinder tem-
perature sen-
sor (see
page 87)
58
X
X
Cylinder tempera-
ture sensor lead
break
51
X
X
No DHW
heating
Cylinder tempera-
ture sensor 2
shorted out
Check the
cylinder tem-
perature sen-
sor (see
page 87)
59
X
X
Cylinder tempera-
ture sensor 2 lead
break
92
X
X
Control
mode
Solar: Collector
temperature sensor
shorted out
Check sensor
9A
X
X
Collector tempera-
ture sensor lead
break
93
X
X
Control
mode
Solar: Sensor S3
shorted out
Check sensor
9b
X
X
Sensor S3 lead
break
Checking and acknowledging faults
(cont.)
77
Troubleshooting
56
92
550
GB
Summary of Contents for VITODENS 300 WB3A
Page 10: ...Opening the control unit housing 10 5862 570 GB...
Page 14: ...Closing control unit housing and inserting user interface 14 5862 570 GB...
Page 129: ...Parts lists cont 113 Parts lists 5692 550 GB...
Page 130: ...Parts lists cont 114 Parts lists 5692 550 GB...
Page 131: ...Parts lists cont 115 Parts lists 5692 550 GB...
Page 132: ...Parts lists cont 116 Parts lists 5692 550 GB...
Page 133: ...Parts lists cont 117 Parts lists 5692 550 GB...
Page 145: ...129 5692 550 GB...
Page 146: ...130 5692 550 GB...
Page 147: ...131 5692 550 GB...