Internal extension H2
The internal extension is integrated
into the control unit housing. As alter-
native, the following functions can be
connected to relay output
sK
. The
function is allocated via coding
address 53:
&
Central fault message (code 53:0)
&
Cylinder loading pump (code 53:3)
&
DHW circulation pump (code 53:1)
&
Heating circuit pump for heating cir-
cuit without mixer (code 53:2)
An interlock for extractors can be con-
nected to connection
aBJ
.
Extensions for external connections (accessory)
(cont.)
99
Function description
56
92
550
GB