Displayed
fault code
Const.
Weat-
her-
comp.
System
character-
istics
Cause
Remedy
94
X
X
Control
mode
Solar: Cylinder
temperature sensor
shorted out
Check sensor
9C
X
X
Cylinder tempera-
ture sensor lead
break
9F
X
X
Control
mode
Solar control unit
fault message
See solar
control unit
service
instructions
A7
X
Control
mode
Faulty operating
interface
Replace
operating
interface
b0
X
X
Burner
blocked
Flue gas tempera-
ture sensor short
circuit
Check the
flue gas tem-
perature sen-
sor (see
page 88)
b8
X
X
Flue gas tempera-
ture sensor break
b1
X
X
Control
mode
Communication
fault
–
program-
ming unit (internal)
Check con-
nections and
replace the
programming
unit, if neces-
sary
b4
X
X
Emissions
test mode
Internal fault ana-
log converter
Replace con-
trol unit
b5
X
X
Control
mode
Internal fault
Replace con-
trol unit
b7
X
X
Burner
blocked
Boiler coding card
missing, faulty or
incorrect card
inserted
Plug in the
boiler coding
card or
replace, if
faulty
Checking and acknowledging faults
(cont.)
78
Troubleshooting
56
92
550
GB
Summary of Contents for VITODENS 300 WB3A
Page 10: ...Opening the control unit housing 10 5862 570 GB...
Page 14: ...Closing control unit housing and inserting user interface 14 5862 570 GB...
Page 129: ...Parts lists cont 113 Parts lists 5692 550 GB...
Page 130: ...Parts lists cont 114 Parts lists 5692 550 GB...
Page 131: ...Parts lists cont 115 Parts lists 5692 550 GB...
Page 132: ...Parts lists cont 116 Parts lists 5692 550 GB...
Page 133: ...Parts lists cont 117 Parts lists 5692 550 GB...
Page 145: ...129 5692 550 GB...
Page 146: ...130 5692 550 GB...
Page 147: ...131 5692 550 GB...