background image

                     P/N 473915000

      

[240011792, Rev. B 7/17/2017]

Homeowner Instructions

Information and specifications outlined in this manual in effect at the

time of printing of this manual. Slant/fin Corp. reserves the right to

discontinue, change specifications or system design at any time without 

notice and without incurring any obligation, whatsoever.

Check our website frequently for updates: 

www.slantfin.com

OIL-BURNING EQUIPMENT

HIGH EFFICIENCY HOT-WATER BOILERS

NOTICE

1. 

Read and save these instructions for reference.

2. 

Use only #2 fuel oil. Do not use gasoline, 

crankcase drainings, or any oil containing 

gasoline.

3. 

Never burn garbage or paper in the unit, and 

never leave combustible material around the 

boiler. Do not stack items on or around the 

appliance within the required clearance to 

combustibles.

4. 

Ensure the supply of combustion air to the 

appliance is not obstructed or cut off. Ensure 

the proper ventilation to the appliance area is 

maintained.

5. 

Do not tamper with unit or controls call your 

service agent.

 WARNING

Maintenance and Service must be completed by 

qualified agency.
Modification, substitution or elimination of factory 

equipped, supplied or specified components may 

result in personal injury or loss of life.
TO THE OWNER - Installation and service of this 

boiler must be performed by a qualified installer.
TO THE INSTALLER - Leave all instructions with 

boiler for future reference.

!

  

SLANT/FIN CORP.

100 FOREST DRIVE

GREENVALE, NY 11548

www. slantfin.com

 WARNING

Fire, explosion, asphyxiation and electrical shock 

hazard.  Improper maintenance and service could 

result in death or serious injury.  Read this manual 

and understand all requirements, including use of 

qualified agency where directed. 

!

  

Summary of Contents for 473915000

Page 1: ...ithin the required clearance to combustibles 4 Ensure the supply of combustion air to the appliance is not obstructed or cut off Ensure the proper ventilation to the appliance area is maintained 5 Do not tamper with unit or controls call your service agent WARNING Maintenance and Service must be completed by qualified agency Modification substitution or elimination of factory equipped supplied or ...

Page 2: ...ustion chamber Chimney vent only does not apply to direct vent boilers diameter hole is required in the flue pipe between boiler and barometric damper to take draft CO2 smoke and temperature readings Adjust air shutter on oil burner to obtain trace of smoke Measure CO2 at this point Increase air adjustment to lower CO2 by one half 1 2 percent to one 1 percent Verify zero 0 smoke and correct draft ...

Page 3: ...ee of dirt lint and oil to maintain proper air fuel requires to burn Boiler Cleaning Instructions Have a qualified service technician perform cleaning Shut off all electrical power to boiler burner and shut off fuel supply Remove 4 bolts for access to combustion chamber If boiler is equipped with flexible fuel lines swing door open Remove vent connector Remove baffles for cleaning 4 5 6 section bo...

Page 4: ... qualified service technician before remodeling for annual service maintenance before extended periods of shutdown and before start up SLANT FIN CORPORATION Greenvale N Y 11548 Phone 516 484 2600 FAX 516 484 0933 Canada Slant Fin LTD LTEE Mississauga Ontario ...

Reviews: