Coding in
the as
delivered
condition
Address:
value
Function mode
Coding
change
Address:
value
Possible change
53:1
Function relay 2 of the
internal extension:
DHW circulation pump
53:0
Function relay 2: Central
fault
53:2
Function relay 2: External
heating circuit pump
(heating circuit without
mixer)
53:3
Function relay 2: External
cylinder loading pump
54:0
Without solar control
unit
54:1
With Vitosolic 100
54:2
With Vitosolic 200 (auto-
matic adjustment on
recognition)
Domestic hot water
56:0
DHW temperature
adjustable from 10 to
60 °C
56:1
DHW temperature adjus-
table from 10 to 95 °C
(only for gas fired boilers)
Observe the max. per-
missible DHW tempera-
ture
58:0
Without auxiliary func-
tion for DHW loading
58:1
to
58:95
Input of set DHW value 2;
adjustable from 1 to
95 °C (observe coding
address 56)
59:0
DHW cylinder loading:
Starting point -2.5 K
Stopping point +2.5 K
59:1
to
59:10
Starting point adjustable
from 1 to 10 K below the
set value
5b:0
DHW cylinder directly
connected to the boiler
5b:1
DHW cylinder connected
downstream of the low
loss header
60:10
*
1
During DHW loading,
the boiler water tem-
perature is up to 20 K
higher than the set
DHW temperature
60:5
to
60:25
The difference between
the boiler water tempera-
ture and the set DHW
temperature is adjustable
from 10 to 50 K
Code 2
(cont.)
48
Coding
56
92
550
GB
*1
Only for weather-compensated control units.
Summary of Contents for VITODENS 300 WB3A
Page 10: ...Opening the control unit housing 10 5862 570 GB...
Page 14: ...Closing control unit housing and inserting user interface 14 5862 570 GB...
Page 129: ...Parts lists cont 113 Parts lists 5692 550 GB...
Page 130: ...Parts lists cont 114 Parts lists 5692 550 GB...
Page 131: ...Parts lists cont 115 Parts lists 5692 550 GB...
Page 132: ...Parts lists cont 116 Parts lists 5692 550 GB...
Page 133: ...Parts lists cont 117 Parts lists 5692 550 GB...
Page 145: ...129 5692 550 GB...
Page 146: ...130 5692 550 GB...
Page 147: ...131 5692 550 GB...