Coding in
the as
delivered
condition
Address:
value
Function mode
Coding
change
Address:
value
Possible change
F7:24
will be started 1 to 24
times per day for
10 minutes respectively
F7:25
*
5
In "Standby mode", the
internal circulation pump
is permanently ON
Resetting the coding to the delivered condition
1.
Press
L
and
G
simultaneously
for approx. 2 seconds.
2.
Press
e
.
Confirm "Basic setting? Yes"
with
d
.
With
a
or
b
, you can select
"Basic setting? Yes" or "Basic set-
ting? No".
Code 2
(cont.)
62
Coding
56
92
550
GB
*5
Only for constant temperature control units.
Summary of Contents for VITODENS 300 WB3A
Page 10: ...Opening the control unit housing 10 5862 570 GB...
Page 14: ...Closing control unit housing and inserting user interface 14 5862 570 GB...
Page 129: ...Parts lists cont 113 Parts lists 5692 550 GB...
Page 130: ...Parts lists cont 114 Parts lists 5692 550 GB...
Page 131: ...Parts lists cont 115 Parts lists 5692 550 GB...
Page 132: ...Parts lists cont 116 Parts lists 5692 550 GB...
Page 133: ...Parts lists cont 117 Parts lists 5692 550 GB...
Page 145: ...129 5692 550 GB...
Page 146: ...130 5692 550 GB...
Page 147: ...131 5692 550 GB...