C
DHW cylinder flow G1½"
D
Gas connection
E
DHW cylinder return G1½"
F
Heating return G1½"
G
Expansion vessel
H
Cable arrangement area
K
Recommended dimension
L
Condensate drain
1.
Prepare the water connections.
Thoroughly flush the heating sys-
tem.
2.
Prepare the gas connection
according to TRGI or TRF or all
local regulations.
3.
Prepare the electrical connections.
&
Mains cable: NYM-J 3 x 1.5 mm
2
,
fuse max. 16 A, 230 V~, 50 Hz.
&
Accessory cables: NYM with the
required number of conductors
for the external connections.
&
All cables in area
H
should pro-
trude 1200 mm from the wall.
Preparations for boiler installation
(cont.)
5
58
62
570
GB