Installation
vacon • 27
Local contacts: https://www.danfoss.com/en/contact-us/contacts-list/
5
5.
I
NSTALLATION
5.1
VACON
®
OPTEA Advanced Dual port Ethernet drive support
The VACON
®
OPTEA Advanced Dual Port Ethernet option board can be used with the following
VACON
®
AC drives. Option board can be used for PROFINET IO with PROFIsafe communication in
slot E, when OPTBL/OPTBM/OPTBN is installed to slot D. If PROFIsafe is not used, then OPTEA can
be installed to slot D too.
Table 10. OPTEA supported AC drives and slots
VACON
®
100 family support
The VACON
®
100 family AC drives are supported from the OPTEA firmware version V002. The
process data in VACON
®
100 family AC drives is 32 bit. The 32-bit process data support is planned
for later firmware release. Only 16-bit process data is supported. PROFIsafe features are supported
only in VACON
®
NXP drives.
EtherNet/IP and Modbus TCP/UDP support
Support for EtherNet/IP, Modbus TCP/UDP and other features which were in OPTE9, were added to
OPTEA firmware V002. Table below shows required minimum AC drive firmware version.
Table 11. Required minimum AC drive firmware versions
AC drive
Slots
From AC drive SW
version on
From OPTEA SW
version on
VACON
®
NXP
D, E
NXP00002V196
V001
VACON
®
100 INDUSTRIAL
and 100 X
D, E
FW0072V028
V002
VACON
®
100 FLOW
D, E
FW0159V018
V002
AC Drive
From AC drive SW version on
VACON
®
NXP
NXP00002V197
VACON
®
100 INDUSTRIAL and
100 X
FW0072V028
VACON
®
100 FLOW
FW0159V018