Commissioning
vacon • 65
Local contacts: https://www.danfoss.com/en/contact-us/contacts-list/
6
Table 19. Emulation mode when installed to VACON
®
NXP drive
When installed to VACON
®
100 family drive and “NX” mode is selected, OPTEA will also emulate C-
series Ethernet option boards and with “VACON100” mode the Vacon100 internal implementations.
Table 20. Emulation mode when installed to VACON
®
100 family drive
It is required to restart the AC drive after you have changed the emulation mode.
See Chapter 6.5 "OPTCx emulation mode" for more details.
6.1.11
MAC Address
This value shows the option board’s device MAC address. The format differs between used VACON
®
AC drive. In VACON
®
100 family AC drives, the format is 00:11:22:33:44:55, and in VACON
®
NXS and
NXP, the value is 001122334455. This value is not visible in VACON
®
20 family AC drives.
Example for VACON
®
100 family AC drive: 00:21:99:1a:00:24
Example for VACON
®
NXS/NXP: 0021991a0024
6.1.12
Modbus Unit Identifier
This value is used to select Modbus unit identifier / slave address. When using Modbus TCP the
value 255 must be used, and this field is ignored as the IP address is used to access the correct
device. When using Modbus UDP the values and their significance is explained in table below. Values
from 1 to 247 and 255 can be set.
The value 0 can be used to control several devices with a broadcast message, e.g. to command all
devices to stop at the same time. This feature will also work if all devices have the unit identifier
value 255.
Value
Emulation mode
Description
1
Normal
Normal operation
2
OPTCx
Emulating OPTC-series ethernet boards as
accurately as possible
Value
Emulation mode
Description
1
Normal
Normal operation
2
NX
Emulating OPTC-series ethernet boards in
VACON
®
100 family type drive
3
V100
Emulating VACON
®
100 family drive
Table 21. Modbus Unit Identifier field description when using Modbus UDP
#
Unit identifier
Description
0
Broadcast
Broadcast address, messages are accepted by all devices
1...247
Slave address
Messages with this unit identifier and broadcast (0) are accepted
255
Non-significant
Messages with all unit identifiers are accepted (setting is ignored)