vacon • 102
PROFINET IO
Local contacts: https://www.danfoss.com/en/contact-us/contacts-list/
8.3.2.5
VACON® specific Telegram 4 and its variants
Use these telegram types (Table 63) as a replacement for the OPT-CP option board, when using
"Bypass mode".
You can also use these telegram types when the PROFIdrive functionality is required and a VACON
®
application with PROFIdrive state machine is activated (e.g. VACON
®
NX Advanced Application).
* See Chapter 8.3.1 "Choosing telegram type".
Table 63. Vendor telegram 4 and variants
Telegram No.
Telegram
Abbreviation
135
Vendor Telegram 4
Vendor 4
136
Vendor Telegram 4 + 4 Process Data
Vendor 4 + 4 PD
137
Vendor Telegram 4 + 8 Process Data
Vendor 4 + 8 PD
146
Vendor Telegram 4 + 12 Process Data
Vendor 4 + 12 PD
147
Vendor Telegram 4 + 16 Process Data
Vendor 4 + 16 PD
Table 64. Vendor telegram 4 setpoint and actual data
Bytes
Setpoint
Actual value
1...2
FB FIXED CW
FB GENERAL SW
3...4
FB SPEED REF
FB SPEED ACT
5...6
PDI1
PDO1
7...8
PDI2
PDO2
...
...
...
19...20
PDI8
PDO8
21...22
PDI9*
PDO9*
...
...
...
35...36
PDI16*
PDO16*