9
vacon • 190
EtherNet/IP
Local contacts: https://www.danfoss.com/en/contact-us/contacts-list/
9.3.2.1.5. A
SSEMBLY
I
NSTANCE
151
* FBProcessDataIn9-16 are available in VACON
®
NXP AC drive. See Chapter 16 "Appendix 6 - Fieldbus
Control and Status Word monitoring values
When using this telegram, monitoring values contains values as shown in the following table. Status
word values depend on used input instance.
Table 184.
Instance
Octet
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
151
(length 38)
0
FBFixedControlWord (Low Octet)
1
FBFixedControlWord (High Octet)
2
FBGeneralControlWord (Low Octet)
3
FBGeneralControlWord (High Octet)
4
FBSpeedReference (Low Octet) in %
5
FBSpeedReference (High Octet) in %
6
FBProcessDataIn1 (Low Octet)
7
FBProcessDataIn1 (High Octet)
...
...
20
FBProcessDataIn8 (Low Octet)
21
FBProcessDataIn8 (High Octet)
22*
FBProcessDataIn9 (Low Octet)
23*
FBProcessDataIn9 (High Octet)
...
...
36*
FBProcessDataIn16 (Low Octet)
37*
FBProcessDataIn16 (High Octet)
Table 185. Control and Status Word monitoring values
Name
Value
Drive CW
FBFixedControlWord
Protocol CW
FBGeneralControlWord