User Manual For - CONTROLLER/DATA RECORDER MultiCon CMC-99/141
–
Return to position
– this parameter is invisible only when the
Looping
parameter is
set as
disabled
. It allows the user to select a section from the list, from which any
next generated Profile should start. In case when the
Section list
is empty, this
parameter is also empty,
Section list sub-menu
It allows the user to configure Profile/timer consisting of up to 100 sections and for each
of them the user can set: Duration, Unit, Shape and Final value.
This button allows the addition of a new section to a list.
This button allows the removal of a section from a list.
The arrows placed in the upper right corner of the screen allow
switching between sections. The middle button allows a direct selection
of a specific section.
The
Section list
parameters are:
–
Duration
– defines the duration of the section, it depends on the
Unit
parameter,
–
Unit
– the user can select available options:
second
,
minute
,
hour
which sets a unit
of the duration,
–
Shape
– allows to choose the shape of the defined section (
const.value
,
slope
),
–
Final value
– allows to set the level for
const.value
, or the end value for
slope
for
the selected Profile/timer,
189