User Manual For - CONTROLLER/DATA RECORDER MultiCon CMC-99/141
Fig. 7.100. View of
External outputs
menu for 'as a relay' type control
Fig. 7.101. View of
External outputs
menu for 'as a linear output' type control
The arrows placed in the upper right corner of the screen let you switch
between a succession of external outputs. The middle button allows
a direct selection of a specific external output from the list.
The parameters that are common for the
External
are:
–
Communication port
- this parameter is read only in the
External outputs
menu,
and indicates the Modbus port number, a description of Modbus ports configuration
and the view of the Modbus port connectors is located in
Chapter 7.15. MODBUS
–
Device
- this parameter is read only in the
External outputs
menu, it shows
the address and name of the SLAVE device configured in the Modbus menu
(
Chapter 7.15.3. Modbus - MASTER mode
–
Output channel
- this parameter is read only in the
External outputs
menu, it
shows the output channel number, type of register and data format configured in
the Modbus menu (each SLAVE device defined in a specific address has its
individually numbered output list),
–
Source
– this parameter allows to choose a source for an external output from
178
Modbus port number
SLAVE device address
The register number of SLAVE device
(HR-HOLDING Register)
Relay mode
The name of SLAVE device
Data format
External output number
Output channel number
1
2
3
5
1