User Manual For - CONTROLLER/DATA RECORDER MultiCon CMC-99/141
Attached with the unit please find:
–
assembly brackets - 2 pieces,
–
pointer for touch screen,
–
user’s manual for
unit (device) in
pdf.
,
4.2.
ASSEMBLY
- The unit is designed for mounting inside housings (control panel, switchboard)
insuring appropriate protection against surges and interference. Metal
housings must be connected to ground in a way that complies with the
governing regulations.
- Disconnect the power supply prior to starting assembly.
- Check the connections are wired correctly prior to switching the unit on.
- In order to install the unit, a mounting hole must be prepared in accordance
. The thickness of the material the panel is made of must not
exceed 5mm. While preparing the mounting hole take the grooves for catches
located on both sides of the housing into consideration (
). Place the
unit in the mounting hole inserting it from the front side of the panel, and then
fix it using the brackets (
). The minimum distances between the centre
points of multiple units - due to the thermal and mechanical conditions of
operation - are shown in
96 x 96 housing:
H, W = 90.5 mm
h = 16 mm
144 x 144 housing:
H, W = 137 mm
h= 38.5 mm
Fig. 4.2. Mounting hole dimensions
12
W
h
8 mm
8 mm
h
1 mm
max. 5 mm
H
1 mm
!
!